background image

EN

VB20-IM-DE-W-UK-05-2023-Rev.1 | Part no. 10079071

3

2 Safety

2.1 Safety notices

!

 WARNING

WARNING indicates a danger arising through incorrect behaviour
(e.g. misuse, disregarding notices, etc.) that may cause serious
physical injury or death.

!

 CAUTION

CAUTION indicates a potentially dangerous situation that may
cause minor or slight injuries if the appropriate safety precautions
are not in place.

 NOTICE

NOTICE indicates a situation that may cause material damage if
the corresponding precautions are not taken.

2.2 Important safety instructions

Before using, carefully read through this operating manual.

Only trained specialist personnel are permitted to perform
maintenance, cleaning and repair work.

The product (VB20) must not be used if it is damaged or is no
longer operating correctly. In this case, contact your specialist
dealer immediately.

Adhere to the maintenance instructions and intervals.

Protect the product (VB20) from the influences of weather.

Never use the product (VB20) outdoor.

The product (VB20) is only permitted to be used for the pur-
pose for which it was intended.

2.3 Intended use

Boiler manifolds VB20 for WATTS pump groups FlowBox DN20.
The product (Boiler manifold VB20) is not intended to be operated
by people (including children) with physical, sensory or mental dis-
abilities, nor by people with insufficient experience or previous
knowledge.

2.4 Foreseeable misuse

The following is considered to be foreseeable misuse:

Operating the product (VB20) contrary to the specifications.

Improper use of the product (VB20).

Modifications to the product (VB20) that were not agreed with
the manufacturer.

Using replacement or wear parts not approved by the manu-
facturer.

Operating the product (VB20) outdoors (parts and compon-
ents are not UV resistant).

2.5 Responsibilities of the operator

The operator must ensure that:

The product (VB20) is only used for its intended purpose.

The product (VB20) is installed, operated and maintained ac-
cording to the specifications in the Installation and Operating
Manual.

The product (VB20) is only operated according to local regula-
tions and occupational health and safety regulations.

All precautionary measures have been carried out to avoid
dangers originating from the product (VB20).

All precautionary measures for first aid treatment and firefight-
ing have been carried out.

Only authorized and trained users have access to the product
(VB20) and operate it.

Users have access to this Installation and Operating Manual at
all times.

2.6 Groups of persons

Only qualified persons may operate the product (Boiler manifold
VB20) or perform service and maintenance work.
User
A user is deemed to be qualified if they have read these operating
instructions and understood the potential risks associated with in-
correct behavior.
Fitter/commissioner
Due to their specialist training and knowledge, and taking into
consideration the applicable standards, provisions, regulations
and laws, a fitter/commissioner is capable of performing work on
the product (VB20) and recognizing and avoiding potential risks.
System planner
The system planner is responsible for evaluating these parameters
and developing workarounds.

Summary of Contents for VB20 Series

Page 1: ...Series VB20 Boiler manifold for FlowBox DN 20 pump groups Installation and operating manual EN WattsWater eu...

Page 2: ...lant operator is responsible for ensuring compliance with the local laws and regulations e g accident prevention regulations etc Incorrect operation or operating the product Boiler manifold VB20 outsi...

Page 3: ...ary to the specifications Improper use of the product VB20 Modifications to the product VB20 that were not agreed with the manufacturer Using replacement or wear parts not approved by the manu facture...

Page 4: ...0 mm Width x height x depth with EPP shell 480 x 154 x 193 mm 721 x 154 x 193 mm Total weight excluding packaging 3 8 kg 6 3 kg including packaging 4 3 kg 6 8 kg Connections to pipe network Heating ci...

Page 5: ...0 10 000 Diagramm Gesamtdruckverlust HKV 2013 xls mbar Pressure loss L h Flow rate 1 outlet open Kvs 11 0 m h 2 outlets open Kvs 14 0 m h VB20 2 1 10 100 1 000 100 1 000 10 000 Pressure loss mbar Flow...

Page 6: ...specified installation positions and flow directions of the parts being replaced CAUTION Material damage Opening shut off valves quickly produces pressure surges Always open shut off valves slowly and...

Page 7: ...rt no 10079071 7 6 3 Installation variants A B A B C D E A B B A C D E 180 180 B A A B E C D E B A B A D C A Return heating circuit B Supply heating circuit C Return boiler circuit D Supply boiler cir...

Page 8: ...al reasons are subject to wear depending on the intensity of use even if the specified care and maintenance have been ob served This especially applies to mechanical parts and parts that could come in...

Reviews: