background image

IS-WR-Radiant_Thermostat-59 330 

4 of 8

Display

Setting

Installer settings. Press the 

 

and 

 

buttons together for 5 more seconds.

AUxILIARY SENSOR 

Select the type of auxiliary sensor. Available when an auxiliary 

sensor is automatically detected. 

NONE

 = no auxiliary sensor, 

ROOM

 = Indoor Sensor, 

OUT

 = Outdoor Sensor, 

FLOR

 = Slab 

Sensor

Room

ROOM SENSOR

Select if the built-in room temperature sensor is on or off. The 

built-in room sensor can only be disabled when an auxiliary room 

or slab sensor is connected.

F

MAX

FLOOR MAxIMUM

Set the floor maximum temperature in order to protect the floor 

covering. Suggested settings: Tile = 90°F (32°C), Wood Floor = 

85°F (29°C)

ESCAPE

Release the   and   buttons to return to the home screen.

For  a  full  list  of  settings  and  operational  details,  please  refer  to  the 

thermostat Installation and Operation Manual that is available from www.

wattsradiant.com

Summary of Contents for Radiant 519

Page 1: ...t Thermostat 519 Quick Setup Guide of 8 2013 Watts Radiant 1 Location 2 Remove Mounting Base 3 Installation to Wall Wall Thermostat Front Thermostat Base Exterior Wall Interior Wall 5 feet 1 5 m Behin...

Page 2: ...d Gang Box Thermostat Front Thermostat Base Adapter Plate 4 Installation to Gang Box 5 Wiring C 518 R Rh W1 S1 Com No Power C 519 R Rh W1 S1 Com No Power Zone Valve 24 V L N R C Optional Floor Sensor...

Page 3: ...gs are essential to the successful operation of the heating system Press Together Display Setting User settings MODE Select heat or off UNITS Select the temperature units in degree Fahrenheit or Celsi...

Page 4: ...NSOR Select if the built in room temperature sensor is on or off The built in room sensor can only be disabled when an auxiliary room or slab sensor is connected F MAX Floor Maximum Set the floor maxi...

Page 5: ...tat Emplacement 1 Retirez la base de montage 2 Installation au mur 3 Mur ext rieur Mur int rieur 5 pi 1 5 m Radiant Thermostat 519 Guide d installation rapide Une soci t de Watts Water Technologies 20...

Page 6: ...ge 5 Interface d utilisateur 6 3 1 4 83 mm Goujon Bo te lectrique Fa ade du thermostat Base de thermostat Plaque adaptrice C 518 R Rh W1 S1 Com No Power C 519 R Rh W1 S1 Com No Power soupape de zone 2...

Page 7: ...ur Param tres Param tres d utilisateur MODE S lectionnez chauffage ou d sactivez unit s S lectionnez les unit s de temp rature en Celsius ou Fahrenheit r tro clairage S lectionnez lorsque le r tro cla...

Page 8: ...e int rieure FLOR sonde de dalle Room sonde d ambiance Choisir si la sonde int gr e de la temp rature ambiante est active ou inactive La sonde d air ambiante peut tre d sactiv e seulement lorsqu une s...

Reviews: