14
Controller Electrical Connections
Power Supply Connections
Installing the Power Supply:
Note: Power Supply includes a harness with 2 black wires
that connect to circuit board, see page 15.
1. Insert black and black transformer wires into 24VDC input
of control.
2510/2750/2815/2850/2900 Valves:
Communication Cables
(for multi-tank systems only)
Hinge Mount: mount
per valve model noted
Wire Harness
Meter Cable
Power Supply
3150/3900 Valves:
Wire Harness
Meter Cable
Power Supply
Communication Cables
Hinge Mount: mount
per valve model noted
44404 Rev A
44403 Rev A
Network / Communication Cables
and Connections
Use a shielded CAT5 Network/Communication cable.
Connect the network/communication cable first before programming.
Cable length between timers/units should not exceed 25 feet.
Connect each unit in series (do not form a loop) together from
one communication port to the next communication port. It does
not matter which one goes to the next one.