STEP 4

 System Start Up 

Step A– 

 Turn on water supply at angle stop and open the Adapt-

A-Valve™ . Turn faucet handle to the open position to start 

the flow of water through the unit . Run 3 gallons of water 

through the unit in order to flush out the normal black car-

bon fines (it will “sputter” until the air is purged out) from the 

unit . Initially, the water may appear cloudy which is due to 

tiny air bubbles and it will clear up shortly . Close the faucet 

when finished .

Step B – 

 Check for leaks . If you have any leaks, shut off the water 

supply to your system, tighten any fittings / housings and 

restart unit .

Check frequently over the next 24 hours to ensure no leaks are 

present

Green Tube Connection

Step A –  

Locate green tube attached to the 

Filter Module . Insert the open end 

of the green 

1

4

" tube into the open 

1

4

" Quick-Connect fitting on the 

Adapt-A-Valve™ making sure the 

tube is pushed in all the way to the 

tube stop .

Step B –

  Connect the green tube from the 

Filter module to the Adapt-A-Valve™ 

that is connected to the angle stop 

valve . Leave enough tube so it is not kinked and cut the 

tube to the desired length .

STEP 5

UF Drinking System Module Mounting

Step A – 

 Determine best location for 

the UF Filter Module to be 

mounted to allow for future 

system maintenance . The 

parts bag has 2 self-tapping 

screws . Using an electric drill 

with a Phillips bit, screw them 

into the cabinet wall 6" apart 

and 16" from the bottom of the 

cabinet .

Note:  Do not cut any UF system tubes at this time

Summary of Contents for PWDWUFKC3 PURE WATER

Page 1: ...DWUFKC3 3 Tools Recommended for Installation 3 Drill a Hole for the Faucet in a Porcelain Sink 3 Punch a Hole for the Faucet in a Stainless Steel Sink 3 How To Use Quick Connect Fittings For Tubing Connections 4 Faucet Installation 5 Adapt A Valve Installation 5 Green Tube Connection 6 UF Drinking System Module Mounting 6 Blue Tube Connection 6 System Start up 6 6 Month System Maintenance 7 Annual...

Page 2: ...le of running at low water pressures does not require a separate water holding tank does not alter the pH of your water and does not require electricity Due to this the PWDWUFKC3 provides a continuous supply of premium quality drinking water directly to your tap System Maintenance Just because you cannot taste it does not mean that it is not there Contaminants such as lead chromium and arsenic to ...

Page 3: ...extreme caution when drilling Watts accepts no responsi bility for damage resulting from the installation of faucet Step A Determine desired location for the RO faucet on your sink and place a piece of masking tape on over where the hole is to be drilled Mark the center of the hole on the tape Step B Using a variable speed drill set on the slowest speed drill a 1 8 pilot hole through both porcelai...

Page 4: ... edges be removed before inserting into fitting Fitting grips before it seals Ensure tube is pushed into the tube stop Push the tube into the fitting to the tube stop The collet gripper has stainless steel teeth which hold the tube firmly in position while the O ring provides a perma nent leak proof seal Pull on the tube to check that it is secure It is a good practice to test the system prior to ...

Page 5: ...o securely tighten the brass nut while continuing to push the tube into the faucet Parts List for Faucet Item Description A Escutcheon Plate B Black Rubber Washer C Black Locating Washer use where a 1 2 hole is available reverse when mounting on stainless steel or when using drilled hole D Lock Washer E Nut F Brass Insert sleeve G Plastic Sleeve H 1 4 Compression Nut A B C D E F G H Adapt A Valve ...

Page 6: ...rs to ensure no leaks are present Green Tube Connection Step A Locate green tube attached to the Filter Module Insert the open end of the green 1 4 tube into the open 1 4 Quick Connect fitting on the Adapt A Valve making sure the tube is pushed in all the way to the tube stop Step B Connect the green tube from the Filter module to the Adapt A Valve that is connected to the angle stop valve Leave e...

Page 7: ... water systems Your system may contain 2 3 or 4 filter cartridges 6 Month System Maintenance Annual Maintenance Order filter by calling Watts at 1 800 224 1299 Item Needed EDP 7100118 Includes 1 Sediment Filter 1 UF Membrane 1 Carbon Block Filter Note Your UF Drinking Water module is equipped with valved heads which will automatically turn off the water supply to each filter when the filter is rel...

Page 8: ...l manufacturer s warranty only For specific product warranty information please visit www watts com or the published literature that comes with your product Any remedies stated in such warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PERMITTED BY APPLI...

Reviews: