background image

Installation, Operation  
and Maintenance Manual

4-Stage Reverse Osmosis Systems
Model PWRO4

IOM-WQ-PWRO4

Important

Please read the entire manual before proceeding with the  

installation and startup. Your failure to follow any attached 

instructions or operating parameters may lead to the product’s 

failure.
Save manual for future reference.

Table of Contents 

Pages

Operational Parameters .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Contents of Reverse Osmosis System .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Tools Recommended For Installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Drill a Hole for the Faucet in a Porcelain Sink  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Punch a Hole for the Faucet in a Stainless Steel Sink .  .  .  .  .  .  .  .  .  .  .  .  . 3
Watts Standard Faucet Installation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Adapt-A-Valve™ Installation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5
Drain Saddle Installation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5
Drill Hole and Connect 

3

8

" Black Tube  

from Faucet to the Drain Saddle   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Green Tube Connection .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Reverse Osmosis Module Mounting   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Red 

1

4

" Tube Connection (from faucet)   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

Check Air Pressure in the Tank   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Tank Tee Installation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Blue Tube Connection (from System)  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7
Final Filter Installation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7
Start Up Instructions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7
6-Month Maintenance  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8
Annual Maintenance   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8
Membrane Replacement  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 9
Procedure for Extended Non-Use (More than 2 months)   .  .  .  .  .  .  .  .  .  . 9
Troubleshooting .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10
Parts List  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 11
Arsenic Facts .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 12
Service Record   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 13
Limited Warranty  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 16

PWRO4

PURE WATER

System tested and certified by NSF International 

against NSF/ANSI Standard 58 for the reduction 

of the claims specified on the performance data 

sheet .

Note:

 Do not use with water that is microbiologically unsafe or 

of unknown quality without adequate disinfection before or after 

the system . Systems certified for cyst reduction may be used 

on disinfected waters that may contain filterable cysts .

Summary of Contents for PURE WATER PWSYS-RO-STD4-50

Page 1: ...be from Faucet to the Drain Saddle 6 Green Tube Connection 6 Reverse Osmosis Module Mounting 6 Red 1 4 Tube Connection from faucet 6 Check Air Pressure in the Tank 6 Tank Tee Installation 6 Blue Tube...

Page 2: ...d other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane recommended change 2 5 years Stage 3 is the heart of the reverse osmosis system the RO membrane This semi permeable...

Page 3: ...s supplies speciality filters that can be used if copper tubing follows the Reverse Osmosis unit Be sure to follow any state or local regulations during installation Drill a Hole for the Faucet in a P...

Page 4: ...ite plastic insert Item 13 into the end of blue tubing with the delrin sleeve Insert the blue tube Item 12 into the faucet stem and secure with nut Item 11 Note DO NOT overtighten nut Standard Faucet...

Page 5: ...tep B The small square black foam gasket with a circle cut out of the middle must be applied to the inside of the drain saddle Remove sticky tape backing and stick to the drain saddle as shown Step C...

Page 6: ...any RO system tubes at this time STEP 8 Red 1 4 Tube Connection from faucet Step A Using the white plastic union found in the parts bag deter mine where the 1 4 red tubing from the faucet and the 1 4...

Page 7: ...stem contains replaceable treatment components that are critical for effective containment reduction Periodic inspection and following proper system maintenance is critical for continued performance S...

Page 8: ...Line Filter Note Sanitizing of unit is recommended Step A Perform steps A through E in the Six Month System Main tenance Note If not sanitizing the system skip to step H Step B Remove the RO membrane...

Page 9: ...he Adapt A Valve clockwise until it stops Step B Open the RO Faucet and allow water to drain from the tank until it is completely empty Removing the Membrane Step A Use a 5 8 wrench to remove the Gree...

Page 10: ...should be 5 7psi See Page 9 4 Noise Water from faucet vent hole or noise from in drain line drain Crimp or restriction Check tubing and straighten or repair as necessary Straighten all drain lines Cl...

Page 11: ...IRGAP FAUCET CHROME 16 7300030 DRAIN SADDLE 3 8 17 7300022 FLOW RESTRICTOR NOT SHOWN 18 7100331 SEDIMENT FILTER 19 7100446 CARBON BLOCK FILTER 20 7300081 FILTER HOUSING LID 1 4 PORTS 21 7300044 FILTER...

Page 12: ...also called chloramine where it does convert trivalent arsenic to pentavalent arsenic may not con vert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water ut...

Page 13: ...Date of Purchase Date of Install Installed by Date 1st stage Sediment 6 months 2nd stage Carbon 6 months 3rd stage Carbon 6 months Final Filter Carbon 1 year TFM Membrane 2 5 years Notes Service Reco...

Page 14: ...14...

Page 15: ...15...

Page 16: ...ated in such warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLE...

Reviews: