4
NOTICE
Please confirm that all items required are included in the kit ready for
assembly and remove from carton.
1. The system can stand upright in the desired location without the need
to affix to a wall with a mounting bracket. However, a mounting bracket
is included as a separate part (Item 1).
2. Place the system in the desired location. Make sure that the location is
level and sturdy enough to support the weight of the wetted system.
3. Turn off the main water supply to the home and open an inside faucet
to relieve any pressure within the plumbing system.
4. Install a supply valve (user supplied) in the supply line and close it.
5. Connect the cold water supply to the inlet of the OneFlow
®
+ system.
6. Using plumbing tape take the two 1" MPT Threaded Adapters (Item 3) and
insert them into the inlet and outlet of the OneFlow
®
+ Housing (Item 2)
as shown in Diagram A.
7. Secure these adapters with the two red adapter Locking Pins (Item 4)
as shown in Diagram A.
8. Place a bucket under the outlet port or run a line from the outlet port
to a drain.
9. Turn the water back on to the house. Slowly open the supply valve to the
OneFlow
®
+ system. Allow the housing to fill with water. Close the supply
valve when a steady stream of water comes out of the outlet port. If the
outlet is flowing into a bucket, water could splash on nearby objects. If
this threatens the safety, value, structure, or appearance of these objects,
protect/remove them or use the outlet hose to drain option.
10. Close the inside faucet.
11. Connect the outlet of the OneFlow
®
+ system to the cold water supply
to the house.
12. Open hot and cold faucets downstream from the OneFlow
®
+ system to
relieve any air from the plumbing system and water heaters. Then close
the faucets.
13. Check for leaks. Repair as needed.
OneFlow
®
+ System Parts
Bracket
Pressure Relief Valve
OneFlow
®
+ Head Assembly
Sediment/Carbon
Filter Cartridge
(20 microns)
OneFlow
®
+ Housing
Multifunction Tool
Outlet Connector
OneFlow
®
+ Scale
Reduction (TAC)
Catridge
Installation Instructions
New system comes with the cartridges and outlet connector
pre-installed. Installer should verify this prior to installation.
How to install your OneFlow
®
+ system can also be found at:
http://thescalesolution.com/residential
MPT Threaded Inlet/
Outlet Adapters (x2)
Inlet/Outlet red Adapter
Locking Pins (x2)
5
7
9
3
1
4
2
6
8
10