background image

Quick Start 

 

With 

 keys Slide the frame 

  inside the top MENU to change operating mode (see Modes description)  

With 

keys change set temperature or adjust what is blinking on the screen. 

 

With 

key switch between actual room temperature and set temperature or validate an adjustment. 

First go to 

  set clock and adjust time (use 

to adjust minutes, press 

OK

, adjust hours, 

OK

,adjust days, 

OK 

 

Go to

  program menu and select built-in week program

 to

  (or edit user program 

  to 

, see 

below) 
 

Go to 

comfort mode and adjust comfort temperature required with 

 keys (Default comfort temp. is 21°C) 

 
 

Go to 

 reduced mode and adjust reduced temperature required with 

keys (Default reduced temp. is 17°C) 

 
 
Finally go to automatic mode. Your 

MILUX 

Chrono-thermostat is now working and follows the program. 

 
 
 

Modes Description 

 
 

Manual COMFORT operating mode : 

Force comfort temperature operation indefinitely or for a few hours or days (see Holiday function). 
By pr or - key the comfort temperature start to blink and can be adjusted. If you wait a few seconds the actual 
room temperature reappears. MILUX regulation will now follow comfort temp. 

 
 
 

AUTOMATIC operating mode : 

MILUX Chrono-thermostat will follow automatically the program according to the actual time. 
By pressing 

+

 

or

 

-

 key you can override the current set temperature until the next change in the program. 

The segment will lit up. Use 

+ / -

 keys to adjust the temporary required temperature. 

At the next program change the will disappear and the program continues without any alteration. 

 

 
 

Manual REDUCED operating mode : 

Force reduced temperature operation indefinitely or for a few hours or days (see Holiday function). 
By pr or - key the reduced temperature start to blink and can be adjusted. If you wait a few seconds the actual 
room temperature reappears. MILUX regulation will now follow reduced temp. 

 

 
 
 

Manual ANTI-FREEZE operating mode : 

(only for Heating systems, HOT operation selected) 
Force anti-freeze operation indefinitely or for a few hours or days (see Holiday function). 
By pr or - key the anti-freeze temperature starts to blink and can be adjusted. If you wait a few seconds the 
actual room temperature reappears. MILUX will keep temperature above freezing. 

 

 

Summary of Contents for MILUX

Page 1: ... COLD operation Easy wiring 2 conductor wire Keypad lock function child safety Battery powered to prevent loss of program and time during power cuts Battery weakness monitoring Battery replacement without loss of program Reset function Measured temperature precision 0 1 C or 0 2 F Set temperature precision 0 5 C or 0 5 F Set temperature range in comfort reduced 5 C 35 C or 41 F 95 F in anti freeze...

Page 2: ...hole of the rear part Use the screws C to mount the rear part on the wall 2 Connect the wires to the connector D Follow the connection diagram 3 Remove the plastic isolator on the batteries to power up the MILUX Then close the MILUX as explained in step 3 of the batteries replacement last page 4 Adjust the time and follow the QUICK START instructions DIM Instructions ...

Page 3: ...d If you wait a few seconds the actual room temperature reappears MILUX regulation will now follow comfort temp AUTOMATIC operating mode MILUX Chrono thermostat will follow automatically the program according to the actual time By pressing or key you can override the current set temperature until the next change in the program The segment will lit up Use keys to adjust the temporary required tempe...

Page 4: ... displays the actual room temperature DANGER IN THIS MODE YOUR INSTALLATION CAN FREEZE because the MILUX is stopped Set CLOCK menu Use this menu to adjust the MILUX clock to the actual time use to Press adjust minutes OK use to Press adjust hours OK use to Press adjust days OK PROGRAM menu By pressing or key the Program number start to blink If you select a built in program to and press OK this pr...

Page 5: ...lace the three LR6 AA 1 5V batteries with new ones IMPORTANT You have 1 minute to change the batteries To close the MILUX Place the front panel in front of the rear part Insert the three contacts in the connector holes Then push the front panel while keeping it parallel to the rear part You can help the button to click by pressing slightly on it ...