background image

 

 
 
 
 
 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

PPL IMP 1185 C 

DISPLAY 

TECHNICAL CHARACTERISTICS

 

 

A programmable electronic thermostat, which 
regulates your heating system where comfort, 
simplicity and energy saving go hand in hand

 

o

 

Weekly programme per minute 

o

 

12 temperature levels (steps) per day 

o

 

Permanent memory storage 

o

 

Regulation by internal probe, external 
probe or a combination of both 
(external probe in option) 

1:

     Functioning mode 

2:

 

Installer’s or user’s menu. 

3: 

Show the block number in program mode, or the program number in AUTO mode. 

4:

     Display of temperature, task, hour or parameter title when “

2

” is indicated. 

5:

     Ambient temperature is indicated. 

6:

     Keyboard locked. 

7:    

The next block (step) of the program is displayed. (Current setting, Temperature and starting hour of the next block)  

9 :

      indicator for: override temperature or 

ITCS

 is running if blinking. 

10 :

     Cooling mode indicator (blinks when operating) 

11 : 

Heating mode indicator (blinks when operating) 

12 : 

Replace batteries. 

13 :

  Days of the week. 

 

Digital chrono-thermostat “Milux Star” 

Your thermostat has 2 menus with configurable parameters.  

 

                                                                   

To enter in the menu, with

key, 

 

move the mode cursor to 

                    

The first menu is meant for the end user. 

Press the

key during 5 seconds. 

 

The second menu is meant for the system installer

Press the

key during 10 seconds 

   

Once you have chosen a menu, go to the parameter which you can change by using 

and

.  

Use the 

and 

 keys to modify the value and confirm with

To leave the parameter menu, choose « 

End

 » and press

.  

     

Parameters 

User’s Menu 

number 

name 

Description of the parameter 

Factory value 

Other possibility 

01 

°C  °F 

Select  a type “°” on the display 

°C 

°F 

02 

12H  24H 

Select type of hour. 

24H 

12H (AM/PM) 

03 

CAL Air 

Calibration of the internal probe 
(The calibration must be done after 12H working with the same setting 
temperature. Check the room temperature with a thermometer and enter the 
reel value) 

Air  

0

°C From 

-5

°C to 

+5

°C 

04 

CAL Flor 

Calibration of the external probe (if connected) 
(The calibration must be done same as above) 

Floor  

0

°C From 

 

-5

°C to +

5

°C 

09 

End 

To exit the user’s menu. 

Press  

 

 

Parameters 

Installer’s Menu 

number 

name 

Description of the parameter 

Factory value 

Other possibility 

11 

ItCS 

The thermostat Intelligent Temperature Control System will activate your 
installation in advance to assure the desired temperature at the hour 
programmed following your weekly program. 

This automatic control system works in the following way: 

When you start your thermostat for the first time, it will measure the time 
taken by your installation to reach the set temperature. The thermostat will 
re-measure this time at each program change to compensate external 
temperature change & influence. You can now program your thermostat 
without the need to adjust the temperature in advance because your 
thermostat does it automatically for you. 

« 

Yes 

» 

Function active 

« 

no 

» 

Function not active 

12 

Out 

Type of output  

« 

nC

» 

Normally closed 

« 

no 

» 

Normally Open

 

13 

PUMP 

Anti-lock-braking function of the pump. When the pump hasn’t worked on a 
particular day, start it up for one minute each day 

« 

Yes 

» 

Function active 

« 

no 

» 

Function not active 

14 

SEnSOR 

Selection of the sensor for regulation 

« 

Air 

» 

or  

Room sensor with 

floor limitation 
If floor sensor 

connected 

« 

Flor 

» 

Floor sensor only 

15 

rEGUL 

Selection of regulation type 

« 

bp 

» 

Proportional band 

« 

hyst 

» 

Static differential of 0.5°C 

16 

t Cy 

Selection of the proportional band duration in minutes 

« 

15 

» 

Slow system adapted 

to each heating type 

Heating application : 

Burner oil « 

20 

» 

Burner gas « 

10 

» 

Zone valve  « 

10 

» 

Heat pump « 

20

» 

Ventilo convector « 

10 

» 

17 

t on 

Minimal starting time in minutes 

« 

002

 » 

Adjustable  

0

 to 

In case of an installation with burner or 
heat pump, it is recommended to adjust 
value  « 

3

 » 

18 

t off 

Minimal resting time between 2 heating cycles in minutes  

« 

003

 » 

Adjustable  

0

 to 

In case of an installation with burner or 
heat pump, it is recommended to keep 
value « 

3

 » 

19 

bP 

Value of the proportional band 

« 

2.0°C

 » 

Adjustable  1°C to +4°C 

A well insulated house « 

1.5C

 » 

A not insulated house « 

4C

 » 

20 

CP 

Compensating value 

« 

0.0°C

 » 

Adjustable 1°C to 12.7°C 

Increase the value according to the 

current load  

21 

FLorLi. 

Lo 

Lower limit of the floor temperature. Only effective if the external probe is 
connected and selected. 

« 

18°C

 » 

From 5°C to «

 FLorLi.Hi

»

 

22 

FLorLi. 

Hi 

Upper limit of the floor temperature. Only effective if the external probe is 
connected and selected. 

« 

35°C

 » 

From «

 FLorLi.Lo

 »to 37°C 

23 

reset ALL  

All parameters are reloaded with default setting values. 

Press  

during a few seconds 

29 

End 

To exit the installer’s menu 

Press  

 

INSTALLER’S AND USER’S PARAMETERS 

Measuring accuracy 

0.1°C  

Operating temperature 

0°C - 50°C 

Ambient temperature range 

5° C – 37° C in steps of 0.5° C 

Characteristics of different 
regulations 

Integral proportional band or Static differential.  

Electrical Protection 

Class II   -   IP30 

Feeding and autonomy 

3 batteries AA LR06 1.5 V /> 2 years (alkaline batteries) 

Output 

Relay 5A 250Vac 

External probe in option 

CTN 10K at 25°C  3 Meters 

Program version 

The version is displayed when the thermostat is turned off  

StAr _ _ _ re 

 

GB 

1

11

10

9

13

2
3

4

5

6

7

12