PPL IMP 1185 C
DISPLAY
TECHNICAL CHARACTERISTICS
•
A programmable electronic thermostat, which
regulates your heating system where comfort,
simplicity and energy saving go hand in hand
.
o
Weekly programme per minute
o
12 temperature levels (steps) per day
o
Permanent memory storage
o
Regulation by internal probe, external
probe or a combination of both
(external probe in option)
1:
Functioning mode
2:
Installer’s or user’s menu.
3:
Show the block number in program mode, or the program number in AUTO mode.
4:
Display of temperature, task, hour or parameter title when “
2
” is indicated.
5:
Ambient temperature is indicated.
6:
Keyboard locked.
7:
The next block (step) of the program is displayed. (Current setting, Temperature and starting hour of the next block)
9 :
indicator for: override temperature or
ITCS
is running if blinking.
10 :
Cooling mode indicator (blinks when operating)
11 :
Heating mode indicator (blinks when operating)
12 :
Replace batteries.
13 :
Days of the week.
Digital chrono-thermostat “Milux Star”
Your thermostat has 2 menus with configurable parameters.
To enter in the menu, with
key,
move the mode cursor to
The first menu is meant for the end user.
Press the
key during 5 seconds.
The second menu is meant for the system installer
.
Press the
key during 10 seconds
Once you have chosen a menu, go to the parameter which you can change by using
and
.
Use the
and
keys to modify the value and confirm with
.
To leave the parameter menu, choose «
End
» and press
.
Parameters
User’s Menu
number
name
Description of the parameter
Factory value
Other possibility
01
°C °F
Select a type “°” on the display
°C
°F
02
12H 24H
Select type of hour.
24H
12H (AM/PM)
03
CAL Air
Calibration of the internal probe
(The calibration must be done after 12H working with the same setting
temperature. Check the room temperature with a thermometer and enter the
reel value)
Air
0
°C From
-5
°C to
+5
°C
04
CAL Flor
Calibration of the external probe (if connected)
(The calibration must be done same as above)
Floor
0
°C From
-5
°C to +
5
°C
09
End
To exit the user’s menu.
Press
Parameters
Installer’s Menu
number
name
Description of the parameter
Factory value
Other possibility
11
ItCS
The thermostat Intelligent Temperature Control System will activate your
installation in advance to assure the desired temperature at the hour
programmed following your weekly program.
This automatic control system works in the following way:
When you start your thermostat for the first time, it will measure the time
taken by your installation to reach the set temperature. The thermostat will
re-measure this time at each program change to compensate external
temperature change & influence. You can now program your thermostat
without the need to adjust the temperature in advance because your
thermostat does it automatically for you.
«
Yes
»
Function active
«
no
»
Function not active
12
Out
Type of output
«
nC
»
Normally closed
«
no
»
Normally Open
13
PUMP
Anti-lock-braking function of the pump. When the pump hasn’t worked on a
particular day, start it up for one minute each day
«
Yes
»
Function active
«
no
»
Function not active
14
SEnSOR
Selection of the sensor for regulation
«
Air
»
or
Room sensor with
floor limitation
If floor sensor
connected
«
Flor
»
Floor sensor only
15
rEGUL
Selection of regulation type
«
bp
»
Proportional band
«
hyst
»
Static differential of 0.5°C
16
t Cy
Selection of the proportional band duration in minutes
«
15
»
Slow system adapted
to each heating type
Heating application :
Burner oil «
20
»
Burner gas «
10
»
Zone valve «
10
»
Heat pump «
20
»
Ventilo convector «
10
»
17
t on
Minimal starting time in minutes
«
002
»
Adjustable
0
to
5
In case of an installation with burner or
heat pump, it is recommended to adjust
value «
3
»
18
t off
Minimal resting time between 2 heating cycles in minutes
«
003
»
Adjustable
0
to
5
In case of an installation with burner or
heat pump, it is recommended to keep
value «
3
»
19
bP
Value of the proportional band
«
2.0°C
»
Adjustable 1°C to +4°C
A well insulated house «
1.5C
»
A not insulated house «
4C
»
20
CP
Compensating value
«
0.0°C
»
Adjustable 1°C to 12.7°C
Increase the value according to the
current load
21
FLorLi.
Lo
Lower limit of the floor temperature. Only effective if the external probe is
connected and selected.
«
18°C
»
From 5°C to «
FLorLi.Hi
»
22
FLorLi.
Hi
Upper limit of the floor temperature. Only effective if the external probe is
connected and selected.
«
35°C
»
From «
FLorLi.Lo
»to 37°C
23
reset ALL
All parameters are reloaded with default setting values.
Press
during a few seconds
29
End
To exit the installer’s menu
Press
INSTALLER’S AND USER’S PARAMETERS
Measuring accuracy
0.1°C
Operating temperature
0°C - 50°C
Ambient temperature range
5° C – 37° C in steps of 0.5° C
Characteristics of different
regulations
Integral proportional band or Static differential.
Electrical Protection
Class II - IP30
Feeding and autonomy
3 batteries AA LR06 1.5 V /> 2 years (alkaline batteries)
Output
Relay 5A 250Vac
External probe in option
CTN 10K at 25°C 3 Meters
Program version
The version is displayed when the thermostat is turned off
StAr _ _ _ re
GB
1
11
10
9
13
2
3
4
5
6
7
12