8
IS-A2C-SC-IntelliFlow 2102
© 2021 Watts
Power MUST be off during installation or servicing of the valve!
Do not plug valve into supply circuit until completion of assembly.
NOTICE
For Vertical Installation Only!
Installing the IntelliFlow
®
Wall Box Unit (A2C-SC-WB)
1. Shut off electrical power supply to the electrical receptacle to be used with the IntelliFlow.
2. Shut off both hot and cold water supply lines.
3. Remove trim plate (Fig. Nos. 5 & 6) and set aside until you’ve completed wall finishing
(painting, wall papering, paneling, etc.).
4. Install the four mounting tabs provided in slots on the sides of the wall box enclosure
(Fig. No. 7).
5. Position the A2C-SC-WB between the wall studs as shown in Fig. No. 7. Check that it
is level and fasten the mounting tabs to the studs.
6. Remove drain plug knock out. Install drain piping and water supply piping to the appro-
priate IntelliFlow connection. Either IntelliFlow connection may be used for the hot or
cold water supply.
Figure 6
(front view)
Trim Plate
Water supply connections
Drain connection
UL
R
LISTED
3P47
Figure 7
(top view)
Finished
Wall
Wall
Studding
Drain
Knockout
Drain
Trim Plate
Mounting
Slots (4)
Mounting
Tabs (4)
16" on center – Typical
WARNING
!
Figure 5
(side view)
Trim Plate
Wall Box