Replacing the Media 

NOTICE

Ion exchange resin may need to be replaced periodically 

due to physical breakdown caused by chlorine/chloramine 

disinfectants, or fouling caused by certain metals such as 

iron and manganese.

  1.  Mark the location of the mineral tanks on the floor incase they 

need to be moved once all water, resin and gravel has been 

removed. This will help with realignment of the plumbing after 

media replacement. DO NOT attempt to move a mineral tank 

that contains media and or water.

  2. Open the bypass valve.
  3.  Close the inlet and outlet isolation valves for the mineral tank 

needing media replacement

  4.  Locate “Manually Initiating a Regeneration” on page 19 of this 

manual and follow the steps to place the system in the back-

wash position. This relieves any pressure inside the mineral 

tank. Once the system cycles into the backwash position, 

unplug the control valve from the power outlet to keep the 

system in the backwash position. 

  5.  Disconnect the inlet, outlet, and drain union plumbing fittings. 

Then, if necessary for the removal of the control valve from 

the mineral tank, remove the remaining plumbing from the 

inlet, outlet and drain ports of the control valve.

  6.  Disconnect the meter cable from the from the from the meter 

dome and from the P5 port located on the back of the control 

valve controller. Store the meter cable in a safe location.

  7.  Disconnect the brine plumbing from the control valve’s brine  

connection port.

  8.  Disconnect the power supply cable from P14 port located on 

the back of the control valve controller.

  9.  If this is an HCTA-300 or HCP-300 series system disconnect 

any interconnecting communication cables from the P1 and 

P3 ports located on the back of the control valve controllers.

10.  Remove the control valve from the mineral tank by loosening 

and removing all flange bolt nuts. Remove flange bolts and 

flange segments then lift up on control valve to disconnect it 

from the tank flange. Store the control valve in a safe location.

WARNING

!

The weight of this control valve exceeds 115 pounds. 

Do not attempt to install or remove control valve 

alone. Team lifting and proper scaffolding should 

be used. A 2" male NPT X Eye Bolt fitting has been 

provided with each control valve. This assembly is 

intended to be threaded into the control valve’s drain 

port (1/2 turn past fully hand tight) and used as a lifting 

point when removing control valve from tank flange.  

11.  Note the top of the distributor tube. It must be flush with the 

top of the tank. If it is above the top of the tank by more than 

1/2" the distributor tube may have become disconnected from 

the distributor screen in the bottom of the mineral and must 

be reconnected.

12.  Obtain a length of 3/4" sch. 40 PVC that is the same height 

as the mineral tank and a length of 1" clear braided poly-vinyl 

hose. The hose must be long enough to reach the nearest 

floor drain. (Both of these can be acquired at a local  

hardware store). 

13.  Insert one end of the pipe inside the hose and the other end 

of the pipe into the top of the mineral tank and down into 

the resin media. Put the other end of the hose inside a water 

permeable bag and locate the bag over the floor drain.

14.  Insert a garden hose into the bag side of the poly-vinyl hose 

to fill the hose and PVC pipe with water. Air will bubble out of 

the tank. Once all the air is out of the hose and pipe, remove 

the garden hose from the polyvinyl hose to establish a 

siphon. The resin can then be siphoned into the bag. Use the 

garden hose to maintain a full water level in the mineral tank 

to. The bag end of the poly-vinyl hose must remain lower in 

elevation then the end of the PVC pipe in the mineral tank 

to maintain the siphon. The bag will retain the resin while the 

water flows down the drain. Use caution not to allow resin to 

enter the floor drain.

15.  Continue to siphon resin until it is completely evacuated from 

the mineral tank. Gravel will clogged the siphon hose and, if 

it must be removed due to fouling, or to repair or replace a 

damaged distributor tube and screen, must be evacuated by 

other means.

16.  If replacing gravel, inspect lower distributor screens for  

damage and replace if necessary.

17.  To add new media and reconnect control valve to mineral 

tank follow General Installation steps 3-4K located on page 9 

of this manual.

18.  Reconnect inlet, outlet, and drain plumbing to the control 

valve and tighten the plumbing union fittings on each of these 

plumbing lines.

19.  Reconnect brine tubing to brine connection port of control valve.
20.  Reconnect meter cable to meter dome. Then reconnect the 

other end of the meter cable to the P5 port located on the 

back of the control valve controller.

21.  If this is an HCTA-300 or HCP-300 series system reconnect 

any interconnecting communication cables to the P1 and P3 

ports located on the back of the control valve controllers.

Summary of Contents for HC-300

Page 1: ... Installation Operation and Maintenance 3 Commercial Water Softeners Series HC 300 HCTA 300 HCP 300 HC 300 Simplex Systems HCTA 300 Duplex Alternating Systems HCP 300 Duplex Triplex and Quadplex Progressive Systems ...

Page 2: ...uality components Simple programming corrosion resistant mineral tank s and an easy to service design ensures this system will be durable and easy to maintain Thank You The Watts Team Softened water provides a wide variety of benefits such as reducing the potential of lime scale formation in boilers water heaters and heat exchangers to protecting the remainder of the plumbing system from costly ma...

Page 3: ...er that is microbiologically unsafe or of unknown quality This system will not make microbiologically unsafe water safe Water that is unsafe must be treated separately from this conditioner Operating ambient temperature 34 to 100 F 1 to 43 C Operating water pressure range 25 to 125psi 171 kPa to 8 6 bar All plumbing connections to the system should be made using industry accepted best practices Pl...

Page 4: ...s where an ion exchange resin is used to effectively exchange calcium and magnesium hardness cations for sodium cations in the water New or freshly regenerated ion exchange resin is saturated with sodium cations As calcium and magnesium hardness cations come in contact with the ion exchange resin they attach to the resin and sodium cations are released into the water This is possible because the h...

Page 5: ...generation B System 7 2 Mineral Tanks 1 Meter Immediate Regeneration C System 14 2 8 Mineral Tanks 2 8 Meters Immediate Regeneration Progressive Flow Tank Staging GPM Threshold for Progressive Feature ________________________________________________ D _____________________________Other System Description 3 Controller Program Settings A Backwash ____________________________________ Minutes B Brine ...

Page 6: ...95 2419 95 2419 108 2743 44 1118 44 1118 42 1067 60 1524 3245 M4118B 39NT 995 8 2530 995 8 2530 1123 8 2854 503 8 1280 503 8 1280 50 1270 60 1524 4295 MODEL NO DIMENSIONS SHIPPING WEIGHT A B C D E F G in mm in mm in mm in mm in mm in mm in mm lbs M4110TA 39NT 797 16 2017 797 16 2017 95 2419 24 622 85 2159 30 762 50 1270 2070 M4112TA 39NT 817 16 2068 817 16 2068 963 4 2457 301 8 765 100 2540 39 991...

Page 7: ... 4015 M4116TA 39NT 68105509 30 Cubic Foot 3 Duplex Alternating Softener with Flow Meter 42 X 144 X 117 6245 M4118TA 39NT 68105523 35 Cubic Foot 3 Duplex Alternating Softener with Flow Meter 50 X 164 X 117 8295 MODEL NO ORDERING CODE DESCRIPTION SPACE SHIPPING REQUIRED WEIGHT D X W X H LBS M4110TI NH 68105475 10 Cubic Foot 3 Progressive Duplex Softener with Flow Meters 59 x 82 x 106 2140 M4112TI NH...

Page 8: ...re missing or damaged contact your Watts representative If they can not be reached contact Watts customer service at 800 659 8400 A B C F E D G H Drain line and brine line flow controllers may come factory assembled on control valve s drain port depending on size Carefully inspect control valve and brine tank packaging for these items before discarding any packaging Distributor tubes ship inside m...

Page 9: ...ome off during media loading 4c Place the distributor tube screen end down into the mineral tank and center it in the bottom The top of the distributor tube should be flush with the top of the tank Test the tape cap to make sure it can not come off during the media loading process 4d Fill the mineral tank 1 3 full with water to prevent breakage of the distributor tube screens during the media load...

Page 10: ...r must point towards the drain receptacle Only plumbing tape is allowed on the drain line flow controller fitting threads System Installation 14 Construct the drain line routing it to an appropriate drain recep tacle abiding buy all local building and plumbing codes DO NOT construct drain line to elevations that exceed 4 feet above the drain port of the control valve or reduce the drain line diam ...

Page 11: ...unplug the control valve from the power outlet to keep the system in the backwash position 6 Open the inlet isolation valve slightly until water can be heard flowing through the isolation valve and allow the mineral tank to fill with water Air will come out of the drain line until the mineral tank is full of water Once water flow at the drain line is observed fully open the inlet valve and allow w...

Page 12: ...outlet headers need to be sized according to flow rate requirements by others 13 Power requirements 115v 60hz 2 7 Amps per control valve unless otherwise specified 14 Brine tank must be located within 10 feet of system control valve and on a common floor elevation with mineral tank to ensure proper brine draw operation 15 Use a minimum of 1 inch sch 40 pvc piping for construction of brine line 16 ...

Page 13: ...LVE NORMALLY CLOSED HEADER PIPE SEE NOTE 12 OUTLET SEE NOTE 12 3 FLOW METER SAMPLE PORT OUTLET UNION ISOLATION VALVE SEE NOTE 4 OUTLET PIPE Drain and Brine Connection Detail for HCTA 300 Series Drain water out to drain Brine Flow Control Attach to brine tank brine connec tion port with flow arrow pointing towards the brine tank See Top View installa tion image Control valve drain connection Drain ...

Page 14: ...VC PIPING SEE NOTE 15 MINERAL TANK BRINE TANK SEE NOTE 14 INLET UNION ISOLATION VALVE SEE NOTE 4 INLET SEE NOTE 12 SAMPLE PORT INLET PIPE DRAIN LINE SEE NOTE 10 BYPASS VALVE NORMALLY CLOSED HEADER PIPE SEE NOTE 12 OUTLET SEE NOTE 12 SAMPLE PORT OUTLET UNION ISOLATION VALVE SEE NOTE 4 3 FLOW METER OUTLET PIPE VACUUM RELIEF SEE NOTE 8 ...

Page 15: ...able Power Supply 3150 3900 Valves Wire Harness Meter Cable Power Supply Communication Cables Hinge Mount mount per valve model noted 44404 Rev A 44403 Rev A HC 300 HCTA 300 HCP 300 Systems use 3900 Type Control Valves Network Communication Cables and Connections Use a shielded CAT5 Network Communication cable Connect the network communication cable first before programming Cable length between ti...

Page 16: ...16 Wiring Diagram 44403 Rev A Wiring diagrams are reference only All wiring should be done by a certified electrician and meet all electrical codes ...

Page 17: ...rds menu navigation Network two to eight valves via shielded CAT5 cables LED Status Indicator Blue In Service Flashing Blue Regeneration Queued Green Regeneration Flashing Green Standby Red Error condition present Two Programmable Auxiliary relay outputs Time based Volume based Chemical pump Alarm based Cycle based Standby Remote input Remote Lockout Remote Regeneration Easy installation with plug...

Page 18: ...18 Controller Display ...

Page 19: ...regeneration If regeneration occurs for any reason prior to the delayed regeneration time the manual regeneration request shall be cleared Pressing the Extra Cycle button while in regeneration will cause the upper drive to advance to the next step immediately Controller Operation During Regeneration In the Regeneration Cycle step display the controller shows the current regeneration cycle name the...

Page 20: ...mote Regeneration Ability to trigger a regeneration via a remote input Regeneration Types Softener Filter Meter Delayed When volume remaining reaches zero and the scheduled regeneration time is reached default 2 a m softener 12 a m filter the unit will regenerate Softener Filter Meter Immediate When volume remaining reaches zero the unit will regenerate Time Clock Once volume remaining reached zer...

Page 21: ...on the NXT2 circuit board Activates during selected cycle step Activates upon selected start time Range 0 91 minutes Deactivates upon selected end time Range Start Time plus 1 minute Activates when selected volume gallon is reached Range 0 99999 Selected duration in seconds Range 0 9999 seconds System 8 2 Units Alternating Delayed Immediate Transfer Delayed Regeneration One tank online sup plying ...

Page 22: ...rogramming certain values may not be able to be viewed or set 7 The controller will display local information not system information 8 In the event of a regeneration occurring while displaying master programming the regeneration step and time remaining will be displayed When regeneration has been completed the display will return to the main screen Example On View settings without the ability to a...

Page 23: ...le button to advance to the next value Press the Left button to retreat to the previous value 3 Where applicable use the Up and Down buttons to adjust a value as desired 4 After progressing through all available values the controller will return to Normal operation 5 To exit diagnostic mode progress through all cycles or press hold Left button at any time or simply wait 5 minutes and controller wi...

Page 24: ...isplayed When regeneration has been completed the display will return to the main screen Example Real time flow rate reading Example Peak flow since last regeneration Example Gallons at the outlet since installation Example Reserve Capacity setting Example Gallons at the outlet since last regeneration Example Time since last regeneration Example Installed software version Example Total number of r...

Page 25: ...wn buttons to adjust as desired 3 Press the Extra Cycle button to advance to the Month field Press the Up or Down buttons to adjust as desired 4 Press the Extra Cycle button to advance to the Calendar Day field Press the Up or Down buttons to adjust as desired 5 Press the Extra Cycle button to return to the normal display screen NOTE Press and hold the Left button to exit without saving Time of Da...

Page 26: ...X X X X X X X X Off Immediate Delayed Auxiliary 1 2 X X X X X X X X X X Off Alarm Based Cycle Based Time Based Lock Window 1 2 X X X X X X X X X X On Off Meter Type X X X X X X X X Paddle 0 75 1 1 5 2 3 Turbine 0 75 1 25 1 5 Generic Continuous Flow Detect X X X X X X X X On Off Save as Non Factory X X X X X X X X X X On Off Lock Settings X X X X X X X X X X Off Delayed Enter Code Time Based Day Ov...

Page 27: ... fully hand tight and used as a lifting point when removing control valve from tank flange 11 Note the top of the distributor tube It must be flush with the top of the tank If it is above the top of the tank by more than 1 2 the distributor tube may have become disconnected from the distributor screen in the bottom of the mineral and must be reconnected 12 Obtain a length of 3 4 sch 40 PVC that is...

Page 28: ...ue to flush the resin bed until water at the drain is clear 23 After resin bed flushing is complete reconnect the power supply cable to the P14 port located on the back of the control valve controller Plug the system back in to the power outlet so that it will return to the service position 24 Fully open inlet and outlet isolation valves and close bypass valve 25 Check for leaks and repair as requ...

Page 29: ...MXF F 42 SOFTENER 2 1 68104691 K4560710 15 BRINE FLOW CONTROLLER ASSEMBLY 15 GPM 1 MXF F 48 SOFTENER 3 1 68108485 V2003 A 15 DRAIN FLOW CONTROL 15 GPM PVC 1 MXM F 24 SOFTENER 3 1 68108500 V2005 A 25 DRAIN FLOW CONTROL 25 GPM PVC 1 5 MXM F 30 SOFTENER 3 1 68108502 V2005 A 35 DRAIN FLOW CONTROL 35 GPM PVC 1 5 MXM F 36 SOFTENER 3 1 68108508 V2006 50 DRAIN FLOW CONTROL 50 GPM PVC 2 MXM F 42 SOFTENER 3...

Page 30: ... CAPACITY SAC NA FORM 10 68100354 A7005A MEDIA GRAVEL 20 FLINT 06 X 125 11 68100356 A7006A MEDIA GRAVEL 25 X 125 12 1 68102512 G2009A BRINE TANK ASSY 30X50 BLK W 900 AIR CHECK 12 1 68102509 G2008C BRINE TANK ASSY 39X48 BLK W 900 AIR CHECK 12 1 68102554 G3015 1 BRINE TANK ASSY 39X60 BLK W 900 AIR CHECK 12 1 68102556 G3020A BRINE TANK ASSY 42X60 BLK W 900 AIR CHECK 12 1 68102558 G3025A BRINE TANK AS...

Page 31: ...MBER DESCRIPTION 1 1 68104640 K4560416 NT UPPER POWERHEAD F 3900 24V NTXT2 W POWER SUPPLY F 120V USA WO COVER 2 1 68104580 K4560240 COVER F 3150 3900 UPPER POWERHEAD 3 1 68104399 K4519791 02 ELECTRONIC METER CABLE 25 4 1 68104471 K4544164 POWER SUPPLY CABLE 120V 24VDC F NXT2 3 2 1 4 ...

Page 32: ...32 NXT2 Controller Assembly NXT2 CONTROLLER ASSEMBLY ITEM NO QTY PART NUMBER DESCRIPTION 1 1 68104777 K4562115 CONTROLLER ASSEMBLY NXT2 1 ...

Page 33: ...33 NXT to NXT2 Conversion Kit NXT TO NXT2 CONVERSION KIT ITEM NO QTY PART NUMBER DESCRIPTION 1 1 68104778 K4562121 01 CONTROLLER ASSY CONV KIT NXT TO NXT2 W POWER SUPPLY FOR USA 1 ...

Page 34: ...ent Parts 3900 Lower Powerhead 3900 LOWER POWERHEAD ITEM NO QTY PART NUMBER DESCRIPTION 1 1 68104642 K4560058 03 LOWER POWERHEAD F 3900 24V NTXT2 WO COVER 2 1 68104581 K4560240 22 COVER F 3900 LOWER POWERHEAD 1 2 ...

Page 35: ...EMBLY DOWNFLOW F 3150 3900 UPPER 3 1 68104560 K4560131 SEAL SPACER KIT F 3150 3900 UPPER 4 1 68104542 K4560107 00 PISTON ASSEMBLY DOWNFLOW HWBP F 3900 LOWER 4 1 68104543 K4560107 10 PISTON ASSEMBLY DOWNFLOW NHWBP F 3900 LOWER 5 1 68104562 K4560132 SEAL SPACER KIT F 3900 LOWER 6 1 68104308 K4516345 ORING 362 TANK TO VALVE F 3900 7 1 68104333 K4516800 ORING 238 F 3900 DISTRIBUTOR PILOT 1 1 1 2 4 5 7...

Page 36: ...ne Valve 1800 BRINE VALVE ASSEMBLY ITEM NO QTY PART NUMBER DESCRIPTION 1 1 68104501 K4560036 02 BRINE VALVE ASSEMBLY 1800 BRASS DESIGN 3 1 1 68104582 K4560276 01 BRINE VALVE ASSEMBLY 1800 BRASS RETROFIT KIT TO UPDATE TO DESIGN 3 1 ...

Page 37: ... 08 INJECTOR NOZZLE 1800 8 YELLOW 2 1 68104249 K4515128 09 INJECTOR NOZZLE 1800 9 VIOLET 2 1 68104250 K4515128 10 INJECTOR NOZZLE 1800 10 BLACK 3 1 68104237 K4515127 04 INJECTOR THROAT 1800 4 GREEN 3 1 68104238 K4515127 05 INJECTOR THROAT 1800 5 RED 3 1 68104239 K4515127 06 INJECTOR THROAT 1800 6 WHITE 3 1 68104240 K4515127 07 INJECTOR THROAT 1800 7 BLUE 3 1 68104241 K4515127 08 INJECTOR THROAT 18...

Page 38: ...tronic Meter 3 INCH STAINLESS STEEL METER ASSY ITEM NO QTY PART NUMBER DESCRIPTION 1 1 68104758 K4561935 10 METER ASSEMBLY 3 STAINLESS STEEL ELECTRONIC MECHANICAL 2 1 68110068 K4561939 METER DOME MECH ELEC STANDARD RANGE FOR 75 3 METER W O RING 1 2 2 ...

Page 39: ...egeneration Inlet of control plugged due to foreign material broken loose from pipes by recent work done on plumbing system Remove piston and clean control valve Loss of mineral through drain line Air in water system Assure that well system has proper air eliminator control Check for dry well condition Improperly sized drain line flow control Check for proper drain rate Iron in conditioned water F...

Page 40: ...lected system type in Master Programming Push correct valve settings in Master Settings Motor Stall No Changes Detected in the Optical Sensor for 6 Seconds The motor is on but no encoder pulses are detected within a given duration while homing Check the P11 connection and trigger a manual regeneration Motor Run On No CAM Switch Change Detected The motor is on but no encoder pulses are detected or ...

Page 41: ...d out the drain If optional no hard water by pass piston is used water flow to service outlet is prevented by an extension on the service outlet until the end of the rapid rinse cycle or brine tank refill cycle depending on options chosen Hard water enters at valve inlet flows thru injector nozzle and throat to draw brine from the brine tank Brine flows down thru the mineral into the bottom distri...

Page 42: ...und the piston and out the drain Hard water enters at valve inlet flows thru nozzle and thru throat to brine valve to refill the brine tank Inlet flow also con tinues down thru mineral to the bottom distributor Conditioned water flows up thru the distributor tube around the piston and out the outlet Note An option is available to keep service valve in by pass position until the end of brine tank r...

Page 43: ...43 Flow Data and Injector Draw Rates Down Flow 3900 Valve 3 Dist Tube on 24 Tank 3900 on Empty Tank ...

Page 44: ... media are also not covered by this warranty In the event of a covered defect within the warranty period the Company will at its option replace or recondition the product without charge Disclaimer of Warranty THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT THE COMPANY MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED THE COMPANY...

Reviews: