background image

Dual Sensing Air & Floor Thermostat with sensor
Dimensions:  3-3/8" x 3-3/8" (85.7 mm x 85.7 mm)

The Watts Dual Sensing Thermostat has the ability to sense the 

temperature of the air, floor or a combination of air and floor. Each Dual 

Sensing Thermostat comes with an internal air sensor. The optional 

external 10k sensor which allows detection of floor temperatures is 

included. The external sensor does not have to be used if the Dual 

Sensing Thermostat is to detect air temperatures only.

Dual Sensing Thermostat

Optional Floor Sensor (included)

Installation & Operation

To mount the thermostat remove the thermostat cover by removing the 

white Screw Cover (located in the center of the thermostat cover) and 

the Cover Screw. Secure the Base Unit to the wall. Be sure to feed the 

electrical wiring (18-2) through the provided slot in the Base Unit and 

connect to appropriate terminal block(s). Replace the Cover, Cover Screw 

and Screw Cover.
If floor sensing is desired, make sure the floor sensor is connected to the 

corresponding floor sensor terminals (labeled NTC, the first two terminals 

on the left terminal block). It may be necessary to adjust the J6 setting. 

See wiring diagrams for details.
Change batteries when the Low Battery indicator appears on the  

display. Batteries can be changed before indicator appears if necessary.

Changing Values

To enter the parameter menu, press and hold the OK button for 

5 seconds. 
Use the +/- keys to select the installation parameter to be adjusted. Press 

OK to toggle the parameter setting or to edit its value. When the value 

begins to blink, use the +/- keys to adjust its value. Press OK to select the 

adjusted value. Use the +/- keys to select the next parameter and repeat.
Toggle to “End” and press OK to exit the installation parameter menu.

Description

Order #

Dual Sensing Thermostat, Air/Floor w/sensor

0955317

Description

Property

Operation Voltage

AA Battery

Contact

10A Relay

Sensor

NTC 10K Thermistor

Static Differential

1.0ºF (0.6ºC)

Proportional

10 min. for 3.5ºF (1.9ºC)

Built-in manual setback 7.0ºF (3.9ºC)
Air Temp Range

41.0 - 99.0ºF (5.0ºC - 37.2ºC)

Floor Temp Range

41.0 - 99.0ºF (5.0ºC - 37.2ºC)

Screw Cover

Cover Screw

+/- Adjustment and

Temperature Set Buttons

Mounting Screw

Base

Digital Display

Cover

ES-Dual-Sensing-Thermostat

For Residential or Commercial Radiant Heating Applications

Job Name   ––––––––––––––––––––––––––––––––––––––––––– 

Contractor   ––––––––––––––––––––––––––––––––––––––––––––

Job Location   ––––––––––––––––––––––––––––––––––––––––– 

Approval   –––––––––––––––––––––––––––––––––––––––––––––

Engineer   ––––––––––––––––––––––––––––––––––––––––––––– 

Contractor’s P.O. No.   –––––––––––––––––––––––––––––––––––

Approval   ––––––––––––––––––––––––––––––––––––––––––––– 

Representative   ––––––––––––––––––––––––––––––––––––––––

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts 

Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any 

obligation to make such changes and modifications on Watts products previously or subsequently sold.

ºC

ºF

10.0

50.0

15.0

59.0

20.0

68.0

25.0

77.0

30.0

86.0

35.0

95.0

!

 CAUTION

This Engineering Sheet is not intended to provide full installation 

instructions and safety information. In order to avoid property 

damage or injury, please refer to the complete installation manual 

and product safety information provided with the product.