background image

2

1.    The installation 

MUST BE

 in compliance with BS 6173:2001-Installation of gas-fired catering appliances 

for use in all types of catering establishments (1st, 2nd and 3rd family gases).

2.   Installation and testing 

MUST BE

 carried out by a Gas Safe registered installation engineer.

3.    Cleaning solutions and chemicals must not come into contact with any part of the gas hose. This 

includes acids, solvents, fluxes, chlorinated chemicals etc. In the event of contact with the gas hose, 

rinse immediately with clean water and dry thoroughly.

4.    Contact with sharp objects, wiring etc. and surfaces at temperatures in excess of 105 degrees celsius 

shall be avoided.

5.    Bending and flexing of hoses should be limited to movement required to carefully push and pull  

appliance into and out of position for cleaning and maintenance.

6.    Gas hoses are for use with 1st, 2nd, and 3rd family gas, operating at a pressure not in excess of 

50mbar.

7.   End fittings are bonded into the ends of the gas hose, and no attempt should be made to remove them.
8.   Once fitted, gas hoses must not be reused on another appliance or at another location.
9.    

THE HOSE ASSEMBLY MUST BE FITTED SO THAT GAS ENTERS THE FEMALE HALF OF THE 

QUICK-DISCONNECT COUPLING AND EXITS THE MALE (NIPPLE) HALF. DIRECTION ARROWS ARE 

PERMANENTLY MARKED ON THE QUICK-DISCONNECT COUPLING.

10.   Never insert screwdrivers, probes etc. into the quick-disconnect coupling. This will damage the valve 

assembly.

11.  Never allow the gas hose to be kinked, twisted, torqued or pinched when installed.
12.  Ensure that only the restraining device supplied with the Dormont hose is fitted. The restraining  

device must be used when the appliance is in service, and should be inspected as part of the regular 

maintenance and safety procedures.

13. Use only one gas hose per appliance.
14.  For installations where greater mobility is required, Dormont Swivel MAX® gas hose assemblies are 

recommended.

15.  Quick-disconnect coupling must be disconnected prior to maximum movement of appliance to avoid 

over extending the gas hose. Whenever the appliance is moved for cleaning or maintenance, the  

instructions contained within this booklet must be followed.

Flexible Gas Hose

Installation and  

Operating Instructions

WARNING

!

WARNING

!

Read this Manual BEFORE operating this equipment.
Failure to read and follow all safety and use information can result in death, 

serious personal injury, property damage, or damage to the equipment.
Keep this Manual for future reference.

Summary of Contents for Dormont 2650NPVF36

Page 1: ...Flexible Gas Hose Installation and Operating Instructions To be left with the operator after installation KM 39643 BS 669 2 1997...

Page 2: ...MUST BE FITTED SO THAT GAS ENTERS THE FEMALE HALF OF THE QUICK DISCONNECT COUPLING AND EXITS THE MALE NIPPLE HALF DIRECTION ARROWS ARE PERMANENTLY MARKED ON THE QUICK DISCONNECT COUPLING 10 Never inse...

Page 3: ...e offset from each other refer to figure 2 7 The quick disconnect coupling must be fitted so that the gas enters the female half valved of the coupling and exits the male nipple half Follow the gas fl...

Page 4: ...RP BENDS THE CORRECT WAY TO INSTALL METAL HOSE FOR VERTICAL TRAVERSE IS WITH A SINGLE NATURAL LOOP AVOID SHARP BENDS THAT STRAIN AND TWIST THE METAL HOSE AVOID TWISTING THE HOSE DO NOT ALLOW THE HOSE...

Page 5: ...the gas hose assembly or to any point which is insufficiently anchored Refer to Fig 3 NB The following instructions relate to using the standard restraining kit available with our hoses If the option...

Page 6: ...nipple gas hose assembly to disconnect The nipple gas hose cannot be disconnected until the valve is in the off position To reconnect 1 Firmly push the quick disconnect nipple gas hose assembly into t...

Page 7: ...move the appliance away from the wall 7 Carry out the cleaning process making sure no cleaning solution or foreign substance comes into contact with either half of the quick disconnect coupling or th...

Page 8: ...nterprise Drive Export PA 15632 USA 724 733 4800 FAX 724 733 4808 1 800 DORMONT 367 6668 IOM D 441A 1807 MECHLINE DEVELOPMENTS LIMITED Telephone 44 0 1908 261511 Email info mechline com Web www mechli...