background image

PKW/EKW-IM-DE-B-EN-01-23 Rev.0

41

Inch

G

H

I

ø J

ø K

L

M/M1

Weight  

(kg)

1/2"

59

59

49

81

65

4 x M12

16/2

1,96

68

68

2,44

76

84

3,04

3/4"

59

59

54

99

75

4 x M12

18/2

2,66

68

68

3,14

76

84

3,74

98

108

4,90

1/0"

68

68

65

115

85

4 x M12

18/2

3,85

76

84

4,45

98

108

6,23

114

132

7,44

5/4"

68

68

77

140

100

4 x M16

18/2

5,33

76

84

5,93

98

108

7,71

114

132

8,92

3/2"

98

108

86

150

110

4 x M16

18/3

7,21

98

108

8,37

98

108

8,99

114

132

11,67

138

161

13,63

2/0"

98

108

93

165

125

4 x M16

20/3

10,12

114

132

11,33

114

132

12,80

138

161

14,76

5/2"

114

132

110

185

145

4 x M16

22/3

16,33

114

132

17,80

138

161

22,78

176

200

27,43

3/0"

114

132

120

200

160

8 xM16

24/3

19,19

114

132

20,66

138

161

25,64

176

200

30,29

4/0"

114

132

132

220

180

8 xM16

20/3

26,17

138

161

28,13

176

200

35,80

176

200

42,84

Tab. 13-7  Dimensional table PKW with actubar, size G to SW

Summary of Contents for bar PKW

Page 1: ...de 2 2 way automatic valve PKW with bar agturn or actubar EKW IMPORTANT This manual is only valid in conjunction with the manufacturer documentation of the actuator Translation of the original operati...

Page 2: ...ral Safety Instructions 8 2 2 Intended use 8 2 3 Reasonable foreseeable use 8 2 4 Organizational measures 8 2 4 1 Subsequent retrofitting or changes 8 2 4 2 Replacement of defective parts 8 2 5 Protec...

Page 3: ...lation 21 5 3 Installation of ball valve 21 5 4 Mounting the rotary actuator 22 5 5 Pressure test of the pipe section 22 6 Commissioning and operation 23 7 Maintenance and repair 23 7 1 Maintenance of...

Page 4: ...ssure Temperature diagram 34 17 4 Dimensional tables and dimensional drawings Type PKW with bar agturn 35 17 4 1 Dimensional drawing Type PKW with bar agturn 35 17 4 2 Dimensional table Type PKW with...

Page 5: ...60735 Email bar info wattswater com www bar gmbh de IMPORTANT This manual is only valid in conjunction with the manufacturer documentation of the rotary actuator bar pneumatische Steuerungssysteme Gmb...

Page 6: ...tions with danger to life and health of persons due to electrical voltage Corrosive substances The text passages marked with this symbol inform you about dangerous situations caused by corrosive subst...

Page 7: ...rstand the facts and procedures The descriptions in the figures are exem plary and may differ slightly from the actual appearance of your product 1 4 Responsibility of the operating company The instal...

Page 8: ...plosion The automatic valve in combination with an electric actuator is not intended for use in potentially explosive atmospheres as standard For this purpose an electric ac tuator suitable for ATEX a...

Page 9: ...ications which are listed in the following table The different qualifications are characterized by the following skills and knowledge Instructed persons must operate the rotary actuator and be able to...

Page 10: ...Electrical installation X Pneumatic installation X Setting and equipping X Commissioning X Troubleshooting X Cleaning X Troubleshooting repair and maintenance of mechanics X Troubleshooting repair an...

Page 11: ...e the voltage released by a qual ified electrician and secured against being switched on again Let a qualified electrician check that no current is present DANGER Corrosive substances Depending on the...

Page 12: ...ng WARNING Flying parts Splashing medium There is a risk of injury when the valve is removed under pressure or with present medium The disassembly or removal of a pressurised valve causes an uncontrol...

Page 13: ...disassembling CAUTION Hand injuries When mounting the rotary actuator on the valve spindle the rotary actuator is pushed to the connection point flange of the valve When disassembling the rotary actu...

Page 14: ...hird persons out of the danger zone Use appropriate barriers or name supervisors WARNING Danger of being pulled in danger of crushing and locking Danger due to moving parts of the ma chine valve which...

Page 15: ...rotected areas DANGER Danger of explosion An explosion can occur if the following protective measures are not observed Establish an internal electrically con ductive equipotential bonding be tween the...

Page 16: ...essure Exceeding can cause material failure which can lead to sparking Avoid dust accumulation Do not install rotary actuators in pit like cavities if there is a predictable dust accumulation Do not c...

Page 17: ...le and single acting or electrically and is characterized by a long service life and high operational safety Product features Full passage Maintenance free Optionally available with end position feedb...

Page 18: ...ig 3 1 Type plates PKW Fig 3 2 Type plate EKW Legend 1 bar article number 2 Article order designation see data sheet 3 Control pressure range for the pneum rotary actuator 4 Maximum permissible medium...

Page 19: ...aphs and a written proto col before unpacking the product bar GmbH is not responsible for transport damages and can take over no liability for that 4 3 Transport packaging and storage DANGER Suspended...

Page 20: ...of use The products should be transported in their original packaging or on a pallet or similarly supported to the installation site and unpacked immediately before installation When storing before i...

Page 21: ...conditions The minimum space requirement can be found in the dimension drawing or dimen sion table Chapter 17 Annex Technical data 5 2 Before installation Observe the following points before instal la...

Page 22: ...he actuator by bar GmbH for PKW and by Valpes for EKW 5 5 Pressure test of the pipe section The following must be observed when mak ing the pressure test of a pipe section with installed valves Carefu...

Page 23: ...actu ator refer to the manufacturer documenta tion supplied with the actuator 7 2 Maintenance of ball valve Repair and maintenance of the seal and wear parts of the butterfly valve must not be carrie...

Page 24: ...24 PKW EKW IM DE B EN 01 23 Rev 0 9 Repair and spare parts For information on repairing the actuator refer to the manufacturer documentation supplied with the actuator...

Page 25: ...For information on disassembling the actu ator refer to the manufacturer documenta tion supplied with the actuator 10 2 Disassembly of the ball valve from the pipeline If the unit is to be replaced b...

Page 26: ...26 PKW EKW IM DE B EN 01 23 Rev 0 12 EU Declaration of Incorporation Type P...

Page 27: ...PKW EKW IM DE B EN 01 23 Rev 0 27 13 EU Declaration of Incorporation Type E...

Page 28: ...ording to the following directives 2014 34 EU ATEX Richtlinie ATEX directive EU Abl L 96 309 vom 29 03 2014 Die Einhaltung der in den technischen Daten und Sicherheitshinweisen beschriebenen Betriebsb...

Page 29: ...bient temperature Maximal auftretende Oberfl chentemperatur Maximal occuring surface temperature Maximal zul ssige Umgebungstemperatur Maximal permissible ambient temperature T6 85 C 65 C T5 100 C 80...

Page 30: ...30 PKW EKW IM DE B EN 01 23 Rev 0 15 ATEX Declaration of Conformity Type E...

Page 31: ...PKW EKW IM DE B EN 01 23 Rev 0 31...

Page 32: ...32 PKW EKW IM DE B EN 01 23 Rev 0 16 EU Declaration of Conformity Type E...

Page 33: ...lange connection acc to DIN EN 1092 Mounting position any Nominal pressure rating DN 15 50 DN 80 PN 40 DN 65 DN 100 PN 16 Operating pres sure See Pressure Temperature diagram see Chap 17 3 Temperature...

Page 34: ...IM DE B EN 01 23 Rev 0 17 3 Pressure Temperature diagram 0 25 50 75 100 125 150 175 Medium temperature C Operating pressure bar 50 40 30 20 10 DN 15 50 DN 80 DN 65 DN 100 Fig 14 1 Pressure Temperatur...

Page 35: ...Rev 0 35 17 4 Dimensional tables and dimensional drawings Type PKW with bar agturn 17 4 1 Dimensional drawing Type PKW with bar agturn Fig 13 2 Dimensional drawing Type PKW with bar agturn type GD 07...

Page 36: ...61 G 1 4 83 083 208 223 0 80 G 1 4 103 3 2 40 063 165 65 211 0 61 G 1 4 83 075 182 223 0 73 3 G 1 4 95 083 208 232 0 80 G 1 4 103 092 262 240 0 91 G 1 4 109 5 2 0 50 075 182 80 230 0 73 G 1 4 95 083...

Page 37: ...6 12 92 109 11 7 37 3 2 72 88 86 150 110 4 x M16 18 3 12 7 40 84 99 5 11 7 95 92 109 12 8 65 102 116 5 9 10 64 2 0 84 99 5 93 165 125 4 x M16 20 3 11 9 08 92 109 12 9 78 102 116 5 9 11 77 115 133 7 5...

Page 38: ...Tab 13 4 Actuator assignment for bar agturn type GD Actuator assignment for bar agturn type GS Inch DN 4 bar actuators 6 bar actuators 1 2 15 GS 063 08 GS 052 12 3 4 20 GS 063 08 GS 052 12 1 0 25 GS 0...

Page 39: ...1 23 Rev 0 39 17 5 Dimensional tables and dimensional drawings Type PKW with actubar 17 5 1 Dimensional drawing Type PKW with actubar Fig 13 3 Dimensional drawing Type PKW with actubar type AD 018 exe...

Page 40: ...31 G 1 8 109 018 213 239 35 G 1 4 127 3 2 40 006 159 65 224 31 G 1 8 109 008 173 224 31 G 1 8 109 011 215 224 31 G 1 8 109 026 281 248 35 G 1 4 127 037 266 277 40 5 G 1 4 150 2 0 50 011 213 80 231 31...

Page 41: ...5 93 98 108 7 71 114 132 8 92 3 2 98 108 86 150 110 4 x M16 18 3 7 21 98 108 8 37 98 108 8 99 114 132 11 67 138 161 13 63 2 0 98 108 93 165 125 4 x M16 20 3 10 12 114 132 11 33 114 132 12 80 138 161 1...

Page 42: ...26 Tab 13 8 Actuator assignment for actubar type AD Actuator assignment for actubar type AS Inch DN 4 bar actuators 6 bar actuators 1 2 15 AS 006 08 AS 004 12 3 4 20 AS 008 06 AS 006 10 1 0 25 AS 018...

Page 43: ...les and dimensional drawings Type EKW 17 6 1 Dimensional drawing Type EKW B M M1 A D C J K DN G F E Anzahl der Gewinde Gewindegr e number of threads thread size L Fig 14 4 Dimensional drawing Type EKW...

Page 44: ...6 106 128 Tab 14 10 Dimensional table Type EKW size A to E Inch F G J K L M M1 Weight kg 1 2 152 49 81 65 4 x M12 16 2 2 67 3 4 152 54 99 75 4 x M12 18 2 3 37 1 0 152 65 115 85 4 x M12 18 2 4 08 5 4 1...

Page 45: ...Terms and Conditions of Sale and Delivery which has been communicated to the Purchaser in any form without the written consent of a representative of bar GmbH The bar products are comprehensively tes...

Reviews: