Relief Valve Installation

Please follow these instructions to properly install the relief valve to the main body:

For Deringer Models 40/40X/40G/40GX/50/50X/50G/50GX

FLOW

1. Before installing the 
relief valve, make sure 
the O-Ring is in the 
groove on the top of the 
relief valve. Apply a small 
coating of lubricant to 
O-Ring.

2. Mount the relief valve 
to the relief valve port on 
the bottom side of the 
main valve body. 

3. Use a 9/16” wrench 
to attach the two relief 
valve mounting bolts. 
Tighten both bolts.

4. Use an adjustable 
wrench to connect the 
relief valve sensing line 
to the sensing line body    
coupler.  