background image

Series 1156F-N256 Repair Kits

 

ORDERING CODE 

KIT NO. 

SIZES

in. mm

 884390 

1156FRK 

1

2

 15

 878339 

N250RK 

3

4

 20

Kit for No. 1156F and 256 includes all items shown.

IS-1156F    0829 

EDP#1910265

 

© Watts, 2008 

USA:

  815 Chestnut St., No.  , MA 01845-6098; www.watts.com

Canada:

  5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca

W a t e r   S a f e t y   &   F l o w   C o n t r o l   P r o d u c t s

Limited Warranty:

 Watts Regulator Co. (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of 

original shipment.  In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.  

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.  THE COMPANY MAKES NO OTHER 
WARRANTIES, EXPRESS OR IMPLIED.  THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental, special 
or consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting 
from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which the Company has no 
control.  This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the product.  
Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of incidental or consequential damages.  Therefore the above 
limitations may not apply to you.  This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State.  You should consult applicable state laws to 
determine your rights.  

SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF 

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT.

Service

The strainer screen should be serviced at least twice
a year.

This series is a new development for standard capacity domes-
tic water regulation service. It has special unitized construction 
which consists of the seat, disc and stem assembly, and strainer 
screen all together in one unit for complete replacement
maintenance.

To clean or replace parts:

 1. 

 

Close the shutoff valve upstream of the regulator.

 2. 

 

Bleed pressure from system.

 3. 

 

Loosen and remove the fast fi ll cap. Remove the spring 
cage and all parts above the diaphragm.

 4. 

 

Loosen and remove the diaphragm lock nut and lock washer, 
pressure plate and diaphragm from the valve stem.

 5. 

 

Unscrew seat cylinder from body and remove
entire assembly.

 6. 

 

Prior to reassembly fl ush valve to remove sediment.

 7. 

 

After repairs are completed reassemble in reverse order.

Troubleshooting

A dripping Pressure Safety Relief Valve can be an indication that 
the Feed Water Pressure Regulator requires service.

Important: 

The pressure Safety Relief Valve is on the system to 

protect against excessive water pressure only. The function of the 
valve is to release any excess pressure from the system caused 
by thermal expansion of the water. Therefore, do not be alarmed 
at water drippage as the valve is doing what it is designed to do. 
This drippage will not prevent the natural buildup of temperature 
in the boiler because the valve operates on pressure only. The 
valve will open when the gauge pressure reaches 30 lbs.

To avoid water damage or scalding due to valve operation, a 
drain pipe must be connected to the Pressure Safety Relief Valve 
and run to a safe place of disposal.

Never plug the discharge of a pressure safety relief valve!

Other possible causes should also be examined prior to servicing 
the regulator. Some other possible causes are a water logged air 
cushion tank, an over pressurized diaphragm style air cushion 
tank, an undersized air cushion tank and, on systems with a 
domestic water coil, a leak in the tankless coil.

Periodic inspection of the system by a qualifi ed plumbing and 
heating technician is recommended. Corrosive water conditions, 
extremely high water temperatures, unauthorized adjustments or 
repair could render the valve ineffective for the service intended. 
Regular inspection and cleaning of all water safety and control 
valves assures maximum life and proper product and system 
function.

Fast Fill
Lever and
Cap Assembly

Seat and Disc
Assembly

Diaphragm

When ordering, Specify:

1.  Ordering Code Number
2.  Size of Valve
3. Type Number
4.  Model Shown on Nameplate

Stem

Seat Cylinder

Integral
Stainless Steel 
Valve Seat

Strainer
Screen

Disc