Setting The Controller - Continued
4. “96 Hours” is now displayed. Pressing and releasing the CHANGE button
will toggle this on and off.
If “96 Hours” is selected, the appliance will work no more than 4 days without a regeneration. The “96
Hours” selection is required in Europe. Note: If there is iron in your water, select this option.
Pressing and releasing the SET button will advance programming to the next step.
Default is for “96 Hours” to be ON.
5. “Gallons X100” is now displayed. Pressing and releasing the CHANGE button will toggle between
“Gallons X100” and “Liters X1000”. Choosing gallons sets the controller to English units, and choos-
ing liters sets it to metric units. Pressing and releasing the SET button will advance programming to
the next step.
6. If “Gallons” was chosen, “12” is now displayed. If “Liters” was chosen, “24” is displayed. Pressing
and releasing the CHANGE button will toggle between “24” and “12”. This controls the selection of a
12-hour (AM/PM) or 24-hour clock. If 24-hour, 00=midnight. Default is “12”.
7. “Set Time” and “12” is now lit. To set the time, press and hold the CHANGE button to advance the
numerical display, and switch from “PM” to “AM” if appropriate. Note: set the time to the nearest hour.
Pressing and releasing the SET button will save the time displayed and advance to the next menu.
Pressing and releasing the SET button will advance programming to the next step. Default is 12 PM.
8. “Set Reg. Time” and “02” is now displayed. To set the regeneration time, press and release the
CHANGE button to advance the numerical display. Pressing and releasing the SET button will save
the “regen. time” displayed and put the unit into operation. Default is 2 AM.
PROGRAMMING IS NOW COMPLETE
4 Button Error Descriptions
“E1” Error message:
If “E1” appears on the controller screen along with an audible beeping sound,
the controller cannot fi nd the home magnet disk position. Make sure the controller is fi rmly seated on
all four “tabs” of the drive end cap. (See page 14). Note: if all is in place, and the motor and magnet
disk do not turn, it could indicate an obstruction in the valve body.
“E2” Error message:
If “E2” appears on the controller screen along with an audible beeping sound,
the motor is disconnected. Plug in the motor. Wait 30 seconds or unplug/replug the transformer into
the controller to re-set.
“E3” Error message:
Home offset error. Disk didn’t start in proper home location. Controller will
automatically try to reset itself by fi nding Home and continuing the regeneration.
“E4” Error message:
Magnet stuck at home. Gear teeth aren’t engaged, gear stripped, something
is jammed in the valve. Cycle the power to reset.
“E5” Error message:
Memory error. Replace board.
16
Summary of Contents for Sof-Tek
Page 2: ...2 Notes this page left blank intentionally...
Page 17: ...Setting The Controller Continued Controller Layout Figure 10 17...
Page 18: ...Parts Diagrams ELECTRONICS AND CABINET Figure 11 18...
Page 20: ...Parts Diagrams Cabinet and Assemblies Figure 12 20...
Page 24: ...Parts Diagrams I O Adapter Assembly Figure 14 24...