29
23
AmbS ---
View of the measured values of the
external (Ambient) sensor.
“__._”
24
RecS ---
View of the measured values of the floor
sensor connected to the receiver.
“__._”
25
FL.Lo ---
Lower limit of the floor temperature.
“no”
The lower limitation is
not used
From 5°C to
“FL.Hi”
26
FL.Hi ---
Upper limit of the floor temperature.
“no”
The upper limitation is
not used
From
“FL.Lo”
to 40°C
27
reg ---
Selection of regulation type.
“bp”
Proportional band
(PWM)
“hys”
Hysteresis (On/Off)
28
Bp1 ---
Concrete choice.
“uf1”
For liquid concrete
with low thickness
< 6cm
“uf2”
For traditional
concrete with
thickness
> 6cm
29
Bp2 ---
Floor covering choice.
“Fl1”
For tiling
“Fl2”
For wood parquet
(floating or not)