Preparing the Unit for Retrofit – 

Continued

 

2. 

Turn off the supply gas upstream from the unit. 

3. 

Allow enough time for the unit to return to room temperature. 

4. 

Close the water inlet, outlet, and recirculation shut-off valves to the unit. 

5. 

Carefully open the drain  valve while opening the relief valve on the rear of the unit to 
relieve pressure and allow air into the shell. 

 

Do not drain the unit without venting the shell!  A vacuum in the unit may 
displace the head liner causing serious damage not covered by warranty. 

6. 

Remove all panels from the front, top and sides of the unit, to provide access to the heat 
exchanger top plate. 

IMPORTANT! 

Observe local requirements and lockout procedures when 
working on the unit. 

4.

 

Disassembling the Unit 

Disassembling the Unit 

1. 

Referring to Figure 2, remove the 5/8-11 hex nuts and washers from the upper head and 
then remove the upper head.  

2. 

Remove the upper head-liner (copper or other material) and retain it for reassembly. 

3. 

Remove the head release gasket and discard it.  

4. 

Remove the head gasket and discard it. 

 

 

 

Figure 2:  Heat Exchanger Head Configuration 

 

5.

 

Installing the Anode Assembly  

Once the upper head has been removed, refer to Figure 3, below, and complete the instructions 
below to install the anode assembly.  

 CAUTION 

 

 

5/8-11 X 3-3/4” STUD 

5/8-11 HEX NUT 

UPPER HEAD 

SHELL FLANGE  

HEAT EXCHANGER 

UPPER HEAD LINER  
(P/N 123077) 

HEAD RELEASE 
GASKET  
(P/N GP-18556) 

HEAD GASKET  
(P/N GP-18532) 

Reviews: