Watts Industries 22CX Series Manual Download Page 4

4

ON/OFF ELECTROTHERMIC ACTUATORS

Re-order no.67A-0041-IT/1-UK-09-14-Rev.0

Watts Industries Italia S.r.l.

Via Brenno, 21 - 20853 Biassono (MB), Italia
Tel. : +39 039 49.86.1 - Fax : +39 039 49.86.222
e-mail : [email protected]
www.wattsindustries.com

The descriptions and photographs contained in this product specification sheet are supplied by way of information only and are not binding.

Watts Industries reserves the right to carry out any technical and design improvements to its products without prior notice.

22CX 2-wires

Electrical wire connections

Overall dimensions (mm)

(Blue) 

(Brown) 

Thermostat

(Blue) 

(Black)

 

(Brown) 

(Brown) 

(Brown) 

Thermostat

Pump

Relay

1)  Remove handle or cap from the valve body.

2)  Place the actuator and manually tighten the ring nut of the actuator onto the  

 

body valve.  

 

DO NOT use pipe wrenches, spanners or similar.

3) Connect electrical wiring.

Important maintenance notes

Do not remove the cable. Opening the 

22CX series

 actuator will cause 

 

irreparable damage to the device.

Faulty actuators must be replaced as complete sets.

Warning

IP54 is for horizontally or vertically mounting.

Mounting

(Grey

) 

(Blue) 

(Blue) 

22CX 4-wires

40.5

49.5

52

M30 x 1,5