Specifications

Outlets

Type

NEMA 5-15

Number of Outlets

12

Always On

4 Outlets

IP Controlled

8 Outlets

AC Power

Line Voltage

120V, 60Hz

AC Input Connection

IEC C-14

Power Cord Length

6 Feet

Circuit Breaker Rating

15A

UL Current Rating

12A

Voltage Protection Rating (UL 1449 3rd Edition)

500V

Joule Rating

6480 Joules

Surge Component

Ceramic Encased MOV

Protection Modes

L-N, L-G, N-G

Peak Impulse Current

396,000A

Disconnect Circuitry

Yes

Thermal Fuse

Yes

EMI / RFI Noise Filtration

Filter Banks 1 & 2

80 dB, 300 kHz to 100 MHz

Filter Bank 3 (High Current)

80 dB, 300 kHz to 100 MHz

Safe Voltage Disconnect

Over Voltage

138V AC +/- 5V AC

Under Voltage

88V AC +/- 5V AC

Cable / Satellite Circuit

Connections

Gold Plated "F" Connector (1 Input and 1 Output)

Surge Component

Gas Tube

Clipping Voltage

600V

Frequency Range

0MHz - 3.0 GHz

Insertion Loss

< 0.5 dB

Shielded

Yes

Bi-directional

Yes

Phone / LAN Circuit

Connections

RJ45 (1 Input and 1 Output)

Accepts

RJ11 & RJ45

Surge Component

Sidactor & MOV

Clipping Voltage

RJ11:400V; RJ45:250V

Wires Protected

8 Wires

Operating Temperature Range

14 to104°F (-10 to +40°C)

UL Certifications

UL 60950-1, UL 1449, UL 498, UL 497A/B, UL 1283

Dimensions

17” W x 3.5” H x 12.5” D

Connected Equipment Warranty

$50,000

Summary of Contents for WB-600CH-IPVCE-12

Page 1: ...otection with Fireproof MOVs Advanced Ceramic MOV technology reduces risk of fire from surges Surge Disconnect In the event of a catastrophic surge event the WattBox component will sacrifice itself an...

Page 2: ...2 Safe Voltage LED Indicator 3 Surge Protection LED Indicator 4 Ground LED Indicator 5 Input Voltage Meter 6 Output Current Meter 7 USB Charging Ports 8 Utility Outlet Power Indicator 9 Utility AC Out...

Page 3: ...3 CONTROLLED 6 CONTROLLED 8 WB 600CH IPVCE 12 FILTER 1 FILTER 2 ALWAYS ON 1 ALWAYS ON 3 ALWAYS ON 2 ALWAYS ON 4 CONTROLLED 1 CONTROLLED 3 CONTROLLED 2 CONTROLLED 4 CONTROLLED 5 CONTROLLED 7 GROUND LUG...

Page 4: ...n configuring the Wattbox can be found on the included CD Rom and the SnapAV website www SnapAV com Note The WattBox must be connected to the network and the router on before supplying power to the Wa...

Page 5: ...ar wall heaters space heaters or any enclosed space prone to temperature increase CAUTION Proper Cleaning In general the only cleaning necessary for the Component is a light dusting Unplug the Compone...

Page 6: ...ontinues to trip try moving one or more components to another WattBox You may be drawing too much current through one WattBox Component is not receiving power The component is plugged into a switched...

Page 7: ...ion Filter Banks 1 2 80 dB 300 kHz to 100 MHz Filter Bank 3 High Current 80 dB 300 kHz to 100 MHz Safe Voltage Disconnect Over Voltage 138V AC 5V AC Under Voltage 88V AC 5V AC Cable Satellite Circuit...

Page 8: ...Pg 8 WATTBOX 600 Chassis Series Owners Manual Dimensions POWER VOLTAGE CURRENT USB CHARGING SAFE VOLTAGE PROTECTED GROUNDED WB 600CH IPVCE 12 17 00in 3 92in 3 50in 13 10in 12 50in...

Page 9: ...s connected equipment policy extends to the original purchaser of the SnapAV product only and is non transferable Original purchase receipts must accompany any product return or claim for connected e...

Page 10: ...ement equipment or pay the equivalence of replacement equipment 6 OTHER INSURANCE WARRANTIES This coverage is secondary to any existing manufacturer s warranty implied or expressed or any insurance an...

Page 11: ...Pg 11 WATTBOX 600 Chassis Series Owners Manual 2013 Wattbox Contacting Technical Support Phone 866 838 5052 Email Techsupport snapav com...

Page 12: ...2013 Wattbox 130719 1100...