12.  Electrical connection between rail segments shall be disconnected prior to removal of a mechanical  

 

 connection.

 

13.  The system may be supplied by a three phase power system with four individual circuits rated at 20  

 

 

 

amps/120 volts max-imum, or as permitted by local code.

 

14.  No more than 12 duplex receptacles shall be supplied by one circuit. (12 segments Two Duplex, 6 segments  Four  

 

15.  For commercial use only. 

NOTE - Installation must be in accordance with the National Electrical Code and local codes. Electrically interconnected 

tables need to be mechanically connected.

General Rail Assembly Notes

 It is recommended to perform as much of the rail assembly upside-down, keeping in mind how many installers are 

available to flip the run right-side up once assembled. 

 

 

 

If 1 - 2 installers: flip the first rail segment upside down and complete steps 1 & 2. Then flip the  

 

 

 

 

rail right side up and continue with instructions, adding one segment at a time for step 3.  

 

  

 

 

 

If 3+ installers: complete steps 1-4 with the rail flipped upside down. Once complete, flip right 

 

 

 

side up. The length of run will determine how many installers are needed to perform the flip.

If Using Optional Utility Power - 

  

 

1.  The electrical desk plug must be plugged into the utility power when present.

 

2.  This product is for use on a nominal 120-volt circuit and has a grounding plug that looks like the plug  

 

 

 

illustrated in sketch A (see Figure 77.1). Make sure that the product is connected to an outlet having the  

 

 

 

same configuration as the plug. No adapter should be used with this product.

Save These Instructions 

OPERATING INSTRUCTIONS – Please refer to the provided Installation Instructions and User Guide.

POLARIZED PLUG INSTRUCTIONS – To reduce the risk of electric shock, this furnishing has a polarized plug (one 

blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the out-

let, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the 

plug in any way.

SERVICING OF DOUBLE-INSULATED PRODUCTS – In a double-insulated product, two systems of insulation are 

provided instead of grounding. No grounding means is provided on a double-insulated product, nor is a means for 

grounding to be added to the product. Servicing a double-insulated product requires extreme care and knowledge of 

the system, and is to be done only by qualified service personnel. Replacement parts for a double-insulated product 

must be identical to the parts they replace. A double-insulated product is marked with the words “DOUBLE 

INSULATION”, “DOUBLE INSULATED”, or       .

This product is for use on a nominal 120-V circuit. Make sure that the product is connected to an outlet having the 

same configuration as the plug.  No adapter should be used with this product.

Summary of Contents for Edison Workbench

Page 1: ...ASSEMBLY Edison Workbench V 21 0 12 2023 360 394 1300 watsonfurniture com...

Page 2: ...er operate this furnishing if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or dropped into water Return the furnishing to a service center for examinat...

Page 3: ...circuit and has a grounding plug that looks like the plug illustrated in sketch A see Figure 77 1 Make sure that the product is connected to an outlet having the same configuration as the plug No adap...

Page 4: ...crew 125278 M5 Weld Nut 0002706 M5x35mm Button Head Screw 0002707 8 x 3 4 Phillips FlatHead Screw 116755 Additional tools such as a 90 Degree Bit and an 18 Extension are helpful for some steps No torq...

Page 5: ...urface Super Ellipse Surface Modesty Side Panel Support Rail Power Beam Power Supply Cover End Plate Control Box Finishing Ring Switch Lifting Column Wire Manager Clip Coat Hook Energy Chain Bracket O...

Page 6: ...Adjustable Leg Assembly Dual Sided Fixed Height Leg Assembly Single Sided Height Adjustable Left Hand Leg Assembly Single Sided Height Adjustable Right Hand Leg Assembly Single Sided Height Adjustabl...

Page 7: ...uplex Module single sided vs dual sided two duplexes per side vs four duplexes per side into the notch cuts in the center of the Power Beam 1a Place the appropriately sized Power Supply Cover over the...

Page 8: ...each H leg and Lifting Column Assembly into the notch in the underside of the Power Beam with the Lifting Columns pointing towards the center of the Beam 2a Line up the holes in the Mounting Bracket w...

Page 9: ...ch Support Rail to Lifting Columns Flip the Power Beam and H leg assembly upright Align each Support Rail over the top each Lifting Column 3a Secure each Support Rail to each Lifting Column using four...

Page 10: ...Sided Bench Segments place the Segments upright and end to end at the Power Beam End Bracket 4a Insert two 2 Carriage Bolts through the diamond shaped cutout passing through both Bench Segments and se...

Page 11: ...lign Power Harness Outlets with cutouts in the Rail Segment Feed the infeed through the cutout in the bottom of the appropriate Rail Segment Note Infeed can go into any of the cutouts in the rail segm...

Page 12: ...nnect it to the Power Harness 6a Connect each end of a Jumper to an end of the Power Harness from both bench segments 6b Note Jumpers only connect in one orientation arrows on Jumper and Harness will...

Page 13: ...Plates Align an End Plate to the outer ends of the Workbench 7a Place the two 2 threaded studs on each End Plate through the two 2 diamond cutouts on each End Bracket of the Power Beam Secure each End...

Page 14: ...Beam Secure the appropriately Perforated or Solid Side Panels to both sides of the Power Beam making sure to locate the cutouts in front of the power duplexes These panels will secure to the pre inst...

Page 15: ...Control Box into Support Rail 9a Secure each Control Box using two 2 M5 x 35mm Button Head Screws and two 2 M5 Weld Nuts 9b Connect the closer of the two Lifting Columns directly to the Control Box an...

Page 16: ...iately sized worksurface on top of each support rail with the switch facing outwards toward the user 10a Align the mounting locations in the Support Rail with the Brass Inserts in the underside of the...

Page 17: ...tch and Coat Hook Align each Paddle Switch with pilot holes 11a Secure each Paddle Switch using two 2 8 x 3 4 Phillips Flat Head Screws per Switch 11b Align Coat hook with pilot holes 11c Secure each...

Page 18: ...10 x 5 6 Truss Head Screw 122800 12b 12a 12 Secure Wire Managers Clips Align each Wire Manager Clip with each pilot hole 12a Secure each Wire Manager Clip using one 1 10 x 5 6 Truss Head Screw 12b 18...

Page 19: ...x 5 6 Truss Head Screws 13b and the other to the underside of the power beam with two 2 M6 1 0 X 12MM Button Head Screws 13b Lower Energy Chain onto Energy Chain Brackets 13c Secure each Energy Chain...