Revision 1.8 / June 2016
50
Safety instructions (ATEX)
Watson-Marlow MasoSine
- Pump used in production machinery with explosive mixtures will be equipped accordingly in the
factory. The pump specific ATEX sign is printed on the nameplate.
1.1
Maintenance of the bearings
For pumps in series
MR120, MR125, MR130, MR135 and MR150
,
both bearings must be replaced by new
ones after running for 10,000 hours!
1.2
Safety signs
The following ATEX symbols are only given as an example.
The specific ATEX classification is printed on the nameplate and the certificate of conformance provided with every ATEX
pump.
1.3
Pump classification
The pumps are only designed for jobs lasting several days and are therefore assigned to the Device Group II
– Application field
“dust – or gas – explosive areas”!
1.4
Zone classification
The
Watson-Marlow MasoSine
- Pumps can be used in explosive areas of the zone 1 / 21. This corresponds to the category 2
G / D.
It is expressly forbidden to use the pump(s) in the zone 0!
1.5
Classification of the ex-atmospheres
A distinction is made between dust and gas explosive atmospheres. In the model code, the atmosphere is abbreviated with G
(Gas) and D (Dust).
Watson-Marlow MasoSine
- Pumps are only designed for the explosive atmospheres
G
(Gas) and
D
(Dust)!
1.6
Ignition protection
Our pumps are subject to ignition protection "c" constructive safety according to the standard for "non-electric appliances for use
in explosion-risk areas" EN 13463-5
1.7
Temperature classes
For product temperature
EX II 2 G c IIB T4
up to max. 100°C:
EX II 2 D c T=120°C
1.8
Limit values for the pump
The limit values for the pump (max. speed, max. pressure, max. temperature) are stated in the data sheet (see page 4). These
limit values must never be exceeded under any circumstances! This applies in particular when using a frequency converter.
If the pumps are supplied without a drive, the following values apply!
MR120
MR125
MR130
MR135 (RF)
MR150 (RF)
max. pressure *
145 PSI
145 PSI
145 PSI
145 PSI
145 PSI
max. speed *
800 UpM
800 UpM
600 UpM
600 UpM
600 UpM
max. temp. *
+212 F
+212 F
+212 F
+212 F
+212 F
ambient temp.
+10.5 F to +104 F
+10.5 F to +104 F
+10.5 F to +104 F
+10.5 F to +104 F
+10.5 F to +104 F