8
Pump specifications
8.1
Specification ratings
Operating temperature
5 °C to 40 °C (41 °F to 104 °F)
Storage temperature
630: -25 °C to 65 °C (-13 °F to 149 °F)
Humidity (non-condensing)
80 % up to 31 °C (88 °F) decreasing linearly to 50 % at 40 °C (104 °F)
Maximum altitude
2000 m (6560 ft)
Power Rating
630: 250 VA
Supply voltage
100-120 V/200-240 V 50/60 Hz 1 pH (Subject to regional cord sets
and supply)
Maximum voltage fluctuation
+/-10 % of nominal voltage. A well regulated electrical mains supply
is required along with cable connections conforming to the best
practice of noise immunity.
Full load current
630: <1.1 A @ 230 V; <2.2 A @ 115 V
Fuse rating
T2.5AH250V (5x20 mm)
Installation category
(overvoltage category)
II
Pollution degree
2
IP
630: IP31 to BS EN 60529, if supplied with N module then IP66 to BS
EN 60529. Equivalent to NEMA 4X to NEMA 250 *(indoor use -
protect from prolonged UV exposure)
dB rating
630: < 70 dB (A) @ 1 m
Control ratio
630: 0.1-265 rpm (2650:1)
Maximum speed
630: 265 rpm
m-630dun-en-08.2
13
Summary of Contents for 630 Du
Page 81: ...m 630dun en 08 2 81 ...