Part 1: Drive

 

Siting

 

To ensure correct lubrication of the gear box it is important to run the pump 

only while its feet are standing on a horizontal surface. 
It should be situated where there is free air to circulate around the pump and 

where the tubing is allowed to enter the tube clamps without  kinking. 
The 604S/R can be operated at ambient temperatures from 5C to 40C. 

Storage temperatures from -40C to 70C are permissible, but allow time for 

acclimatisation before use.   

Electrical connection

 

The 604S/R operates on single-phase mains electricity supplies only. It will 

accept without modification or switching any voltage from 100V to 240V either 

50Hz or 60Hz.  
Remove the small transparent plate on the rear panel to gain access to the 

terminal block. Route the mains supply cable through the entry point to the 

right of the recess, and couple the cable to the terminal block in accordance 

with the instructions printed prominently on the rear panel. 
Alternative connectors are supplied to screw into the entry point gland. One 

accepts 20mm rigid or flexible conduit, and the other accepts three core 0.75 

square millimetre PVC smooth sheathed mains cable with a outside diameter 

of 4mm to 7mm (via the screwed adapter supplied) so that a flying lead can 

be used. When using a‚ flying lead, ensure that the lead is securely retained 

in the strain relief gland so that IP55 ingress protection is maintained.  
 

Back panel

Power cable
5 to 8mm outside diameter

M20 for direct conduit connection

 

 

Securely replace the transparent plate and the gasket over the recess. 
Ingress protection standard will be compromised if transparent plate is 

not properly replaced. 
 

Should the pump fail to operate, check that mains electricity is available at the 

unit, that the fuse is intact and that the pump is not stalled by incorrect fitting 

of tubing. If the pump is to be used under manual control and fails to operate, 

check that the manual mode has been selected. 
 

There are dangerous voltages (at mains potential) inside the unit. If 

access is required, isolate the pump from the mains before removing 

the cover. 

Failure to 

operate 

Summary of Contents for 604S/R

Page 1: ...lication PB 0175 Issue 2 IP55 ingress protection variable speed high flow pump Installation and operating instruction Drive s Issue 4 EPROM N A Pumphead s 603R Issue 1 Contents Declarations Page 2 604...

Page 2: ...one pump it complies with Machinery Directive 89 392 EEC and EN60204 1 Low Voltage directive 73 23 EEC and EN61010 1 EMC Directive 89 336 EEC and EN50081 1 50082 1 Responsible person A S Balding Manag...

Page 3: ...nty Watson Marlow Limited warrants subject to the conditions below through either Watson Marlow Limited its subsidiaries or its authorised distributors to repair or replace free of charge including la...

Page 4: ...ng that peristaltic pumps are self priming and will hold their prime up to several metres so there may be no need for non return or foot valves nor for the loading valves required on many other kinds...

Page 5: ...el Alternative connectors are supplied to screw into the entry point gland One accepts 20mm rigid or flexible conduit and the other accepts three core 0 75 square millimetre PVC smooth sheathed mains...

Page 6: ...eed control ratio of the 604S R is 50 1 giving a speed range from approximately 4rpm to its rated maximum speed of 165rpm Flow rates The flow rates given below were obtained using Watson Marlow 3 2mm...

Page 7: ...ly degreased slide the rotor into position The rotor is attached to the drive spindle via a split collet and it is important that the rotor retaining screw is fully tightened a torque of 13Nm to preve...

Page 8: ...ty controlled to our own specifications We recommend Marprene tubing whenever it is chemically suitable The Product Codes for the range of tubing suitable are listed below Tubing for 603R pumphead Bor...

Page 9: ...required Guard switch and magnet Grommet MR 0258M SW 0139 MRA0161A GR 0008 and follower roller Drive spares Direction switch MN 0690S Vertical gasket 4 required MR 0506H Wiring harness MR 0771S Gasket...

Page 10: ...operation If the pump needs cleaning use a cloth dampened with water and mild detergent Do not use strong solvents If harmful liquids are spilled on to the pump first switch off the pump and isolate...

Page 11: ...Page 11 Outline drawing...

Page 12: ...ion 5 4 2 5 2 Serial number 5 4 1 I hereby confirm that the equipment specified has not pumped nor come into contact with any toxic or hazardous substances 5 3 Details of substances pumped Signed 5 3...

Reviews: