5.
Using the
∧
/
∨
keys, scroll to
4-20mA input 1
or
4-20mA input 2
option and press
SELECT
.
This depends on which connection the user has connected the sensor to. See "EtherNet/IP™
control wiring" on page 22 section for connection specifications. Only generic sensors which
provide a 4-20 mA output are supported.
6.
Using the
∧
/
∨
keys, select the sensor unit output type and press
SELECT
. Options in table
below depending on sensor type selection:
Table 21 - Sensor units
Flow
Pressure
ul/min
Bar
ml/min
Psi
ml/hr
l/min
l/min