11.
Using the
∧
/
∨
keys, change the value reported when the sensor input is at 20 mA. Once
satisfied with the value press
SELECT.
12.
Depending on the sensor and units selected the maximum values that can be set at below
Table 20 - Sensor pressure limits
Pressure Unit
Minimum
Maximum
PSI
-10.0
75
Bar
-0.689
5.171
Table 21 - Sensor flow limits
Flow Unit
Minimum
Maximum
ul/min
0
60000000
ml/min
0
60000
ml/hr
0
900000
l/min
0
60
l/hr
0
900
Alarm / warning levels
The Warning / error levels screen will then be shown, refer to "Set Alarm and Warning level" on
page 115. The error and warning values will default to the value set at 4 mA and 20 mA. The user
should set up warnings and errors to suit their process.