Phase to phase

200V ~ (ac)

and above

Limit Control

Contacts

(if required)

Tank
Filter

Semiconductor

Fuses

Heater

Description

Crydom

Filter

Watlow

Filter

Single phase 230 v~(ac)

1F25

14-0019

WARNING

Tank filters may suppress desirable communications carried on power
lines in the 150 to 250 KHz region.  The filters may suppress carrier
current such as that used for infant monitors and medical alert systems.
Verify that suppressed carrier current or other desirable
communications on power lines creates no hazard to people or
property.  Failure to observe this warning could result in damage to
property, and or injury to death for personnel.

WARNING

All filter installation and wiring must be performed by qualified personnel
and conform to local and national electrical codes

In-line power filters have been shown to properly suppress EMI; however, these filters must be rated for the entire load current and are
generally more expensive than the tank filter specified.  An In-line filter may be required if carrier current communications are used on

site.

Joe Millanes

Winona, Minnesota, USA

Name of Authorized Representative

Place of Issue

Director of Operations

August 2013

Title of Authorized Representative

Date of Issue

Signature of Authorized Representative

Summary of Contents for DIN-A-MITE Style A

Page 1: ...that your selections are consistent with your application inputs outputs alarms limits etc If the problem persists after checking the configuration of the controller you can get technical assistance f...

Page 2: ...4 Grounding Hardware 6 Front Top Rail Release Tab Pull Down Zero Electrical Clearance Required Clearance for Air Flow and Bending Radius Clearance for Air Flow and Bending Radius Side 98 mm 3 87 in 50...

Page 3: ...his guideline could result in personal injury or death 3 WARNING Only authorized and qualified personnel should be allowed to install and perform preventive and corrective maintenance on this unit Fai...

Page 4: ...System Wiring Example 1 2 3 4 WATLOW DIN A MITE Style A User s Guide PM6C2CA ALAJAAA 98 99 CC CA CB B5 D6 D5 X1 W1 Y1 T1 S1 R1 L4 K4 T2 S2 R2 Coil L1 Neutral DA10 24C0 0000 5 6 7 8 9 10 Heater...

Page 5: ...presses EMI on the power lines See figure below See Table 1 for the correct filter Description Crydom Watlow Filter Filter Single phase 230V ac 1F25 14 0019 Table 1 DIN A MITE EMI Filters WARNING The...

Page 6: ...nubber circuit across its output Remove the RC snubber circuit before placing the DIN A MITE into service DC Contactor 4 5 to 32V dc maximum current 4 5V dc is 8 mA per leg Loop powered linear current...

Page 7: ...EN 61000 4 11 2004 Voltage Dips Short Interruptions and Voltage Variations EN 61000 3 2 2005 Harmonic Current Emissions EN 61000 3 3 2005 Voltage Fluctuations and Flicker3 Notes 1Use of an external fi...

Page 8: ...to people or property Failure to observe this warning could result in damage to property and or injury to death for personnel WARNING All filter installation and wiring must be performed by qualified...

Page 9: ...Email info watlow co uk Website www watlow co uk From outside The United Kingdom Tel 44 115 964 0777 Fax 44 115 964 0071 Asia and Pacific Watlow Singapore Pte Ltd 16 Ayer Rajah Crescent 06 03 04 Singa...

Reviews: