R
A
Y
M
A
X
1
1
2
0
How to Order
To order your stock RAYMAX heater, specify:
•
RAYMAX 1120
•
Quantity
•
Watlow code number (from Watlow Heater's Catalog)
If our stock units do not meet your application needs,
Watlow can manufacture RAYMAX heaters to your special
requirements. For made-to-order heaters, specify the
following:
•
Heated width and length. Three-phase panels must have
width divisible by three.
•
Total wattage of each panel.
•
Exact voltage and phase. A five percent variation in
voltage at the oven will cause a 10 percent variation
in power.
•
Zoning. Indicate dimensions and wattage of each zone.
•
Mounting legs or mounting studs, if desired. For studs,
give number and location, or indicate standard location.
•
Terminal location if non-standard.
•
Terminal box or wire raceway, if required.
Supplying a drawing with an order or request for quotation
can be very helpful in clarifying design information.
Availability
Stock: Next day shipment.
Made-to-Order: Consult Watlow.
Applications and Technical Data
Face Temperature: 1100°F maximum (595°C)
Wattage: Watt densities up to 20 W/in
2
(3 W/cm
2
)
Standard Voltage: 120, 240, 480V
Å
(ac), 1-phase. Balanced
3-phase available on unit widths divisible by three. Other
voltages are available.
Terminals: Non-standard locations are also available.
Please specify.
Standard Dimensions: ±
1
⁄
16
inch (0.0625 mm)
Typical Peak Energy Wavelength: 3-3.5 microns
Specifications
1
9
/
16
"(39 mm)
Overall Width =
Heated Width
+
3
/
8
"
(9.5 mm)
Overall Length =
Heated Length
+ 1
1
/
4
"(31.75 mm)
A B
3
/
8
"(9 mm)
3
/
8
"
(9 mm)
7
/
8
"(22 mm)
1
1
/
2
"
(38 mm)
1
3
/
16
"
(30 mm)
1
1
/
2
"
(38 mm)
Width: inches (mm)
1
(25.4)
36
(914.4)
1 (25.4)
Length: inches (mm)
6 (152.4)
70
(1778)
any
Area: in
2
(cm
2
)
6
(38.7)
864 (5574.2)
any
Note
:
Less than maximum length X width may exceed
maximum area.
Heater Dimensions
Min.
Max.
Increments