background image

RESTARTING INSTRUCTIONS & PRIMING THE PUMP

TROUBLESHOOTING

If the pump is installed below the water level of the pool, close return 
and suction lines prior to opening hair and lint pot on pump. Make sure 
to re-open valves prior to operating.

The pump strainer pot must be filled with water before the pump is 
initially started. Follow these steps to prime the pump. For 2-speed 
pumps: Pump should run on high-speed for priming.

1.  Remove the pump lid.
2.  Fill the pump strainer pot with water.

3.  Reassemble the pump lid onto the strainer pot. The pump is now  
  ready to prime.
4.  Open the manual air relief valve on top of the filter, and stand clear  
  of the filter.
5.  Turn on the switch or time clock.
6.  When water comes out of the manual air relief valve, close the    
  valve. The system should now be free of air and circulating water to  
  and from the pool.
  NOTE: Self-priming pump may take up to 3 1/2 minutes to reach a  
  lift height of 10 feet.

CAUTION: DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged and the pump 
will start leaking. If this occurs, the damaged seal must be replaced. ALWAYS maintain proper water level in 
your pool. If the water level falls below the skimmer opening, the pump will draw air through the skimmer, 
losing the prime and causing the pump to run dry, resulting in a damaged seal.

FAILURE OF PUMP

1.  Pump will not prime, too much air. Remedy:
a. Check suction piping and valve glands on all suction gate valves.
b. Secure lid on pump strainer pot and make sure lid gasket is in place.
c. Check water level to make sure skimmer is not drawing air.

2. Pump will not prime, not enough water. Remedy:
a. Make sure suction lines, pump strainer, and pump volute are full of 
water.
b. Make sure valve on suction line is working and open (some systems 
do not have valves).
c. Check water level to make sure water is available through skimmer.

REDUCED FLOW AND/OR HEAD

1. Air pockets or leaks in suction line. Remedy:
a. See item 1a of this section above.

2. Clogged impeller. Remedy:
a. Turn off electrical power to the pump.
b. Remove the bolts holding the volute to the seal plate.
c. Slide the motor and seal plate away from the volute.
d. Remove the diffuser.
e. Clean debris from impeller. If debris cannot be removed, complete the 
following steps:
  (1) Remove left hand threaded bolt and gasket.
  (2) Remove, clean and reinstall impeller.
  (3) Reinstall left hand threaded bolt and gasket.
f. Reinstall the diffuser and diffuser O-ring.
g. Reinstall motor and seal plate into volute.
h. Tighten bolts securely.

3. Pump strainer clogged. Remedy:
a. Clean suction trap.

WARRANTY

For product registration visit: www.waterwayplastics.com.

For Warranty questions or claims please contact point of purchase.

810-0152.0618

©2018 Waterway Plastics

2200 East Sturgis Road, Oxnard CA 93030 • Phone 805.981.0262 • Fax 805.981.9403

www.waterwayplastics.com • [email protected]

Designed,

Engineered & 

Manufactured 

in the USA.

Summary of Contents for CHAMPS-125

Page 1: ...be given to the owner operator of this equipment NOTE When pump is mounted permanently within 5 ft of the inside walls of a swimming pool you must use No 8 AWG or larger conductor to connect to bondin...

Page 2: ...to the terminal board 5 Make sure all electrical connections are clean and tight 6 Permanently ground the motor using the internal green ground terminal located on the inside of the motor canopy or ac...

Page 3: ...the length of time between filter cleaning it is most important to visually inspect the hair and lint pot basket at least once a week A dirty basket will reduce the efficiency of the filter and heate...

Page 4: ...re operating Do not allow the pump to operate if it has been flooded 5 If a motor has been damaged by water it voids the motor warranty NOTE DO NOT wrap motor with plastic or other air tight materials...

Page 5: ...on a flat surface and tap out the carbon spring seal 11 Clean the seal plate seal housing and motor shaft 1 When installing the replacement ceramic carbon seal use silicone sealant on the metal portio...

Page 6: ...olt Schs 15 805 0238 1 0 Ring 238 16 319 1420 1 Diffuser Plate 17 715 1201 2 3 8 Quarter Slot Plug SdWet End 18 805 0112 2 O Ring 014 20 319 1430 1 Basket Assy 21 805 0436 1 O Ring 6 Trap Lid CHAMPION...

Page 7: ...ll not prime too much air Remedy a Check suction piping and valve glands on all suction gate valves b Secure lid on pump strainer pot and make sure lid gasket is in place c Check water level to make s...

Reviews: