INSTALLATION INSTRUCTIONS
CUSTOM BLOWER LOCATION
If your air bath has a custom blower location, the air manifold might
FOR ALL WATERTECH WHIRLPOOL, AIR, COMBO, & SOAKING BATHS
not be attached to the bath. If not, the installer should permanently
install the air manifold above the baths highest water level so water
WATERTECH RECOMMENDS THAT MOUNTING CABINET AND FINISHED MATERIALS
NOT BE
CONSTRUCTED
AND INSTALLED PRIOR TO RECEIVING YOUR TUB.
can never get to the blower should the air check valve fail.
The blower is shipped in a separate box and should be
installed in the desired location with screws. Attach the 1 ½” ribbed
STEP ONE
blower hose between the manifold & blower with the supplied hose
clamps. Install the control button on a surface of your choice & connect to your blower with supplied cord.
Place the tub on a flat level surface and measure from the bottom of the tub lip to the floor at locations indicated
in the drawing below.
OZONATOR
SURFACE HEATING SYSTEM
Automatically operates when
Operated by 3 mode keypad;
OWNER/INSTALLER BEARS FULL
pump or blower are on OFF(LED off);
RESPONSIBILITY TO MAKE SURE
.
HEAT (30 minutes LED on);
THE BATH WILL FIT THE CABINET
MAINTAIN HEAT (30 minutes LED blinking)
CONSTRUCTED FOR THE TUB
AND ALL INSTALLATION INSTRUCTIONS
ARE FOLLOWED.
INFUSION MICRO BUBBLE SYSTEM
STEP TWO
Turn1 1/2 HP stainless pump & pressure tank
Add ½” to the largest measurement.
ON/OFF by pushing Air Control button on tub deck.
STEP THREE
CUSTOM BLOWER LOCATION
Construct the cabinet the tub will sit in using the dimension from step two. The cabinet top must be level in all
directions and the cabinet depth be measured from the top of the finish material (tile, stone, Corian, etc.) to the
floor.
If your air bath has a custom blower location, the air manifold might
not be attached to the bath. If not, the installer should permanently
install the air manifold above the baths highest water level.
2
This insures water can never get to the blower should the air check
valve fail. The blower is shipped in a separate box and should be
installed in the
OPTIONAL TURBO CHARGING SYSTEM
The turbo charging system is a composed of a single speed, 1 H.P., 675 watt
heated blower, and installation components.
Connect your blower to the manifold as shown using the ribbed air hose and
clamps. The blower is shipped separately for custom placement. Locate the blower
in a convenient space of your choice and install the hose and switch as above.
AIR INJECTOR CLEANING
Each air injector has a 7 hole/port metal strainer cover that snaps inside the injector.
STEP FOUR
Located beneath the strainer is a water tight air check valve. To clean or service an
injector close tub drain to prevent part loss and pry the strainer cover out of the
Place tub in cabinet, check for fit, and make final adjustments.
injector and use needle nose pliers or tweezers to remove the air check valve.
Care should be taken to avoid damaging the spring and valve body.
Clean all parts and reassemble.
MAKE SURE THE TUB
WILL FIT IN THE ROUGH
IMPORTANT SAFETY INSTRUCTIONS
OPENING BEFORE
1.
RISK OF ELECTRICAL SHOCK! DO NOT PERMIT ANY ELECTRICAL APPLIANCES (RADIO,
LIGHT, TELEPHONE, OR TELEVISION) WITHIN FIVE FEET OF THE WHIRLPOOL BATHTUB.
INSTALLING THE
FINISHING MATERIALS.
2.
DO NOT REMOVE THE SUCTION COVERS FROM YOUR WHIRLPOOL TUB.
7
3.
TO REDUCE THE RISK OF INJURY:
A
. Water in your whirlpool should not exceed 104 degrees F. Lower
Temperatures are advised for extended use and definitely for younger children.
B
. Pregnant or possibly pregnant women should consult their Physician before using the whirlpool.
Water temperatures above 100 degrees not recommended.