background image

INSTALLATION &

OPERATION MANUAL

MODEL

:  INF-PR

O1

CERTIFIED

WATER PROTECTION

Summary of Contents for Infinity Protector INF-PRO1

Page 1: ...INSTALLATION OPERATION MANUAL MODEL INF PRO1 CERTIFIED WATER PROTECTION...

Page 2: ...been designed and tested to be used on municipally treated water sources Do not use with water that is microbiologically unsafe or of unknown water quality without adequate disinfection before or aft...

Page 3: ...TY WHERE TO INSTALL 1 CITY WATER INLET WATER METER SERVICE GROUNDED UNSWITCHED 115 VOLT OUTLET SERVICE GROUNDED UNSWITCHED 115 VOLT OUTLET WELL INLET RELIEF VALVE MUST BE INSTALLED PRESSURE TANK PUMP...

Page 4: ...Cap 10 00 010 11 Retaining Ring 10 00 011 12 Replacement Filter INF PRO1 FX DRAIN VALVE Bypass Orientation INLET OUTLET Flow direction arrows on bypass are incorrect for this filter application Plumb...

Page 5: ...er Assembly should be placed on the Outlet Side Note the flow direction arrow on the meter body HAND TIGHTEN ONLY STEP 4 OPTION B Use 7 90 degree Angled In Out 1 MNPT for connecting your plumbing to t...

Page 6: ...g should slide completely out of the groove STEP 5 Remove packaging from filter cartridge then place the filter cartridge into the tank with the double O ring facing down STEP 8 Reposition the Top Cap...

Page 7: ...Cap monitors water and flow rate and provides a visual color coded notification letting you know when the filter has reached certified capacity level at 100 000 gallons and to Replace the Filter GREEN...

Page 8: ...oor drain or bucket and use to drain sediment or to aid in filter removal during change out STEP 5 Push down the top cap with both hands to unseat the retaining ring STEP 8 Remove old filter and disca...

Page 9: ...r comes out of the red depressurization button STEP 22 Check for leaks STEP 14 Reposition the Top Cap into its original location STEP 17 If completed Step 2 then Close the John Guest fitting and shut...

Page 10: ...OS 1 5 10 0 07 53 v NAME AND PART NUMBER SIZE MICRON RATING RATED CAPACITY FLOW RATE PEAK FLOW REDUCTION OF LEAD CHLORINE CHLORAMINE TASTE AND ODOR REDUCTION CAPACITY PRESSURE DROP SPEC Infinity Prote...

Page 11: ...al attack environment accident fire flood freezing Act of God misuse misapplication neglect oxidizing agents such as chlorine ozone chloramines and other related components alteration installation or...

Page 12: ...WaterTech 800 Freeport Pkwy 150 Coppell TX 75019 469 521 1180 CustomerSupport WaterTech com www WaterTech com...