Chapter 2
Using The Boost Box
CalIBRaTIOn:
The Control Unit automatically calibrates
(resets) its internal sensors every time it is turned on. This
precisely calibrates the sensors to the boat’s level position
in the water.
To calibrate the Boost Box:
1. Ensure the boat is in flat water with no rolling waves.
2. Turn the unit on and ensure the LED is steadily
illuminated for 2 seconds.
3. Rotate the selector knob all the way to the off position
(LED should go out) and then rotate clockwise until
the LED begins to flash.
4. The LED will flash slowly, then more quickly. When
the LED is steadily illuminated, the Control Unit is
successfully calibrated.
The Control Unit has an internal memory circuit and will
remain calibrated when the boat power is switched off or if
the unit is unplugged. The unit will re-calibrate only when
the selector knob is rotated off and then turned back on.
imPortAnt note: for best performance, re-calibrate
the unit after adding or removing significant amounts of
ballast from the boat, as this may change the way the
boat sits in the water.
Do not turn the Boost Box on when the boat is moving or
is in rough water. The Control Unit will improperly reset its
calibration, and the system will not function properly.