More Information
Specifications
These are the technical specifications for the HydraPump® Smart Duo:
•
¼
HP Output Power, Single Phase 120V, 60Hz, 3.4A Max
• Pumping Capacity 1,600GPH Max
• Maximum Head 20
Troubleshooting
PRoblem
Possible Causes
SOlutions
Pump will not start
No Power or cord not connected
Check outlet power or plug
in pump
GFCI tripped
Check wiring
Impeller Blocked/Inlet Clogged
Unplug and remove debris
Sensor not activated
Place pump in always mode
or make sure sensor is
touching water
Thermal Shutdown
Let pump cool down
Pump Starts and stops
Too Frequently
Waters is back flowing from the
outlet hose or pipe
Clean and inspect check
valve on the outlet
Too small a pit opening or
suctioning of the surface the
pump is place on
Place the pump in a wider pit
and make sure it is place on
a hard, flat surface
Pump is very slow or
limited
Inlet clogged
Clean debris from the
exterior of the pump
Restriction in the outlet hose
Check for kinks and
restrictions, shorten the
length if possible
Too much li
Reduce the outlet hose
height to improve the flow
rate
08