Maintenance
The UV Module should be replaced every 9,000 hours or 12 months.
1. Locate and turn off the cold water supply valve that feeds the water to the filtration system.
2. Unplug the ballast from electrical outlet and disconnect at connector from the UV Module.
3. Open the handle on your filtration system faucet to drain and depressurize the system.
4. Disconnect the inlet and outlet tubes from the UV module and remove the elbow fittings.
(See “Using Quick Connect Fittings” on Page 3 for instructions on how to disconnect the
inlet and outlet tubes.)
5. Remove old UV Module from holding clips.
6. Attach elbow fittings to new UV module by pushing them firmly into the 1/4” openings at
each end of module.
7. Connect the Inlet tube to the UV Cap (Wire connector end) by pushing the tube firmly into
the elbow fitting.
8. Connect the Outlet tube to the UV Body by pushing the tube firmly into the elbow fitting.
9. Secure the UV module in the filter clips.
10. Close the handle on your filtration system faucet and turn on the cold water supply angle
valve to the filtration system.
11. Inspect for leaks and repair as needed.
12. Clean up any water in the installation area.
13. Plug the Ballast connector into the UV Module connector.
14. Ensure there is no water present in the area before attempting to plug the ballast into a
GFCI electrical outlet. Confirm the status of the lamp by checking for blue “Glow” from the
UV Module cap. If lamp does not turn on, check the electrical outlet.
15. Inspect for leaks over the next 24 hours.