1.0 SPECIFICATIONS

 

1.1 Technical 

Specifications 

 

Ports Performance  

 

When a port is operating at 100Mbps: 

Data Rate: 100Mbps 

 

When a port is operating at 10Mbps: 

Data Rate: 10Mbps 

 

Network Standards

 

100Mbps: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 
10 Mbps: Ethernet IEEE 802.3, 10BASE-T 
Auto-sensing for speed: IEEE 802.3u 

Packet-Processing Between Domains  

 

Filtering and Forwarding Rate from 100Mbps ports: 148,800 pps max  
Filtering and Forwarding Rate from 10Mbps ports: 14,880 pps max.

 

Processing type: Store and Forward 
Auto-learning: 16K address table, shared for all traffic domains 
Packet buffers: 1024KB, dynamically shared on all domains 
Latency (not including packet time):   100 to 10Mbps:  5

µ

s  

 

10 to 100Mbps:  5

µ

 

Path Delay Value

: 50 BT on all ports

 

 

Maximum Ethernet Segment (or Domain) Lengths

 

10BASE-T (Unshielded twisted pair) 

100 m (328 ft) 

 

100BASE-TX (Category (CAT) 5 UTP) 

100 m (328 ft) 

 

100BASE-FX, half-duplex: (multi-mode) 

412 m (1350 ft) 

 

100BASE-FX, full-duplex: (multi-mode) 

2.0 km (6,562 ft) 

Operating Environment

 

 Ambient 

Temperature: 32

º

F to 104

º

F (0

º

C to 40

º

C) 

 Storage 

Temperature: -5

º

C to 160

º

F (-20

º

C to 70

º

C) 

 

Ambient Relative Humidity:  10% to 95% (non-condensing)

 

Power Supply (External) 

 

Input: 

95-125 vac at 60Hz 

 

Output: 

5VDC, 2Amps  

 

Polarity:  center positive, shell negative 

 

Power Consumption: 8 watts typical, 10 watts max.

 

Network Cable Connectors - 

for eight RJ45 shielded female ports and 1 fiber port 

100Mbps:  CAT5 UTP/STP, fiber (50/125, 62.5/125, 9/125 micron) 
10 Mbps: CAT3, 4, 5 UTP  (Note: auto-sensing does not sense cable type)  
Maximum Load per port: 60 mA 

Uplink, Port #1 or 1SW 

Port #1 (switched RJ45) has a manual crossover (MDIX uplink) switch for connection to a 
central switch or to another ES switch (or equal) unit. The uplink port #1 is auto-sensing for 
speed, and its auto-negotiating uplink feature works the same at 10Mbps or 100Mbps and at 
full- or half-duplex mode. 

Full- or Half-Duplex selection on switched Ports #2 or 2SW for ES-FUTP-8 

Manual switch selects fiber port for FDX or HDX.  See Section 4.3 for details.  

Full-Fixed or Auto-negotiation selection on switched Ports #2 or 2SW for ES-CUTP or ES-
FUTP 

 

 

Manual switch selects port #2 for “FF” or “A”.  See Section 4.3 for details. 

Summary of Contents for ES-CUTP-8

Page 1: ...TP 8 Enclosed Ethernet Switches for Workgroups or Classrooms CORPORATE HEADQUARTERS MANUFACTURING CUSTOMER SERVICE 5001 American Blvd W Suite 605 945 37 th Avenue NW Bloomington MN 55437 Rochester MN 55901 Phone 800 441 5319 Phone 800 328 2275 www watersnet com ...

Page 2: ...nnecting Fiber Optic ST type Twist lock 8 3 2 3 Connecting Fiber Optic SC Type Snap In 8 3 2 4 Connecting Fiber Optic MTRJ Type 8 3 2 5 Power Budget Calculations for ES FUTP 8 Fiber Media 8 3 2 6 Connections to NICs which support Auto Negotiation RJ45 ports 8 3 3 Powering the ES FUTP and ES CUTP Switch 9 4 0 OPERATION 9 4 1 Dual Speed Functionality and Switching 9 4 2 Auto negotiation and Speed se...

Page 3: ...ode 2 0 km 6 562 ft Operating Environment Ambient Temperature 32ºF to 104ºF 0ºC to 40ºC Storage Temperature 5ºC to 160ºF 20ºC to 70ºC Ambient Relative Humidity 10 to 95 non condensing Power Supply External Input 95 125 vac at 60Hz Output 5VDC 2Amps Polarity center positive shell negative Power Consumption 8 watts typical 10 watts max Network Cable Connectors for eight RJ45 shielded female ports an...

Page 4: ...r ES FUTP 8 MTRJ Same as ES FUTP 8 but with multi mode MTRJ type fiber connector ES CUTP 8 with all copper ports ES CUTP 8 8 port 10 100Mbps switch with eight 10 100 N way auto negotiating switched ports Includes store and forward switching that filters and forwards data moving between the ports The internal switch has 16K nodes address table and 1MB packet buffers External power supply Waters Net...

Page 5: ...t all times LEDs to indicate operating status of all ports are mounted on the top There are power PWR and ERROR self test at power up failed indicators for the unit For each port there are Link and Activity LINK ACT LEDs indicating traffic and speed ON for 100Mbps and full half F H duplex indicators The DC power plug connector or jack is in the left rear of the chassis The external power supply is...

Page 6: ...imal frame latency they will also permit bad frames to propagate out to the Ethernet segments connected The cut through technique permits collision fragment frames which are a result of late collisions to be forwarded to add to the network traffic Since there is no way to filter frames with a bad CRC the entire frame must be present in order for CRC to be calculated the result of indiscriminate cu...

Page 7: ...mixed speed requirements like surfing the Internet or downloading data from servers or other sources Some users operate at 100Mbps and some users and utility devices such as print servers run at 10Mbps High performance users need a high bandwidth backbone for access to a central LAN and central file servers The ES FUTP 8 serves this requirement economically The eight full and half duplex switched ...

Page 8: ...nits 3 1 Location of the Switch The location of the switch is dependent on the physical layout of the network The enclosed compact housing makes it ideal to be conveniently mounted on a wall in an office classroom or lab area It can also be mounted or set on a shelf desk or table Locate an AC receptacle that is within six feet 2 meters of the intended switch location The rugged metal enclosure of ...

Page 9: ...of the fiber connectors Save these dust caps for future use 2 Wipe the ends of the dual connectors clean with a soft cloth or lint free lens tissue dampened in alcohol Make certain the connectors are clean before connecting Note One strand of the duplex fiber optic cable is coded using color bands at regular intervals you must use the color coded strand on the associated ports at each end of the f...

Page 10: ...ion properly with NICs Network Interface Cards which support auto negotiation and the Fast Link Pulse FLP coding for the 100BASE TX signaling system When connecting a NIC to the ES FUTP or ES CUTP it may be necessary to reload the NIC drivers on the user device if the NIC has been communicating with a protocol other than 100BASE TX such as 10BASE T When 100Mbps operation is agreed and in use the S...

Page 11: ...ing so that as nodes are added or removed or moved from one segment to another the switch automatically keeps up with node locations An address aging algorithm causes least used addresses to fall out in favor of new frequently used addresses To reset the address buffer cycle power down and up 4 2 Auto negotiation and Speed sensing All eight RJ45 ports independently support auto negotiation for spe...

Page 12: ...s can be set to FDX manually making typical 100Mbps media converters which can be troublesome with auto negotiating ports defaulting to 100Mbps half duplex usable in either HDX or FDX mode as set by the user For the ES CUTP 8 the switched port 2 at F position supports only 100Mbps fixed full duplex 5 0 TROUBLESHOOTING All Waters Network Systems Ethernet switching products are designed to provide r...

Page 13: ...l returns for repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number contact Waters Network Systems Customer Service at 800 328 2275 office hours 8AM 5PM Central Standard Time or email to netinfo wtrs com When calling please have the following information readily available Name and phone number of your contact person Name of your company institution Your s...

Page 14: ...aid to Waters This warranty will not be effective if in the opinion of Waters Network Systems the product has been damaged by misuse misapplication or as a result of service or modification other than by Waters Waters Network Systems reserves the right to make a charge for handling and inspecting any product returned for warranty repair which turns out not to be faulty This device complies with Cl...

Reviews: