Waterra HYDROLIFT-2 Owner'S Manual Download Page 2

WATERRA HYDROLIFT-2

OWNER'S MANUAL

WATERRA HYDROLIFT-2

ASSEMBLY & OPERATION

Assembly & Operation

When using a Waterra Hydrolift-2

pump to

purge and sample a monitoring well, it is very impor-
tant that the Hydrolift be firmly attached to the well.
If the pump is not properly attached it may fall off the
casing causing injury and possibly damaging the pump
and other equipment. Hang the Hydrolift-2 on the
PVC or protective casing by the front forks on the
Hydrolift. The Hydrolift is supplied with a

ratchet

tie-down belt

. The belt is looped through the gap

behind the front forks of the Hydrolift and around the
protective casing and tightened until the Hydrolift is
firmly attached to the casing.

Open the Tubing Clamp

located on the

adjustable clamp arm and place the tubing in the
clamp’s jaws, leaving enough tubing (approximately 5
feet) above the jaws to allow the tubing to reach the
tubing discharge clamp, and then tighten the clamp
until the jaws are completely closed.The tubing clamp
is designed to accept 1" OD, 5/8" OD and 1/2" OD
polyethylene or Teflon tubing. Now position the tub-
ing such that it will not chafe on the well casing and
lock the clamp arm in place by inserting the clevis pin
through the fork and the mating hole in the clamp
arm.

Features

The

Waterra Hydrolift-2

is an elec-

trically powered mechanical drive
mechanism which pumps water by
repeatedly lifting and dropping a tubing
and footvalve assembly that is extended
below the water surface in a well. The
Hydrolift-2 components include a 700
watt (3/4 hp) electric D.C. motor inte-
gral with a 15:1 gear reducer which dri-
ves a linear pump mechanism.This drive
mechanism includes a sliding post that
extends beyond the pump body and
supports the tubing clamp arm. The

pump is designed to hang from the protective well casing and is secured in
place with a ratchet belt.All components on the pump are fully adjustable to
permit operation in wells of varying diameters. The pumping speed is also
fully adjustable to accommodate variable well depths and flow rate require-
ments.

Safety First

Stand clear

of the Hydrolift-2 when in use.The rapid up and down motion

of the drive shaft creates a potential hazard.

Always secure your pump to the well casing securely before starting the
pump, making sure that adequate clearance exists between the reciprocating
shaft and the well head. Never move the pump when connected to a power
source.

Before starting

your Waterra Hydrolift-2 pump, be sure that there is

enough tubing (approximately 5 feet) between the tubing clamp and the tub-
ing discharge clamp. Also ensure that the tubing clamp and pump are posi-
tioned so that the tubing will not chafe on the well casing. Lastly, ensure that
the Hydrolift-2 is firmly strapped onto the protective casing or PVC pipe and
will not come loose while in operation.

Waterra Hydrolift-2

Ratchet tie-down belt

Tubing clamp

Clevis pin and clamp arm

Reviews: