INSTRUCTION MANUAL & WARRANTY – WaterPro DT42 PUMP 

 
 

   

                                                           

 

 
 
 

APPLICATION: This pump is fit for purpose when installed correctly according to these instructions;   
For pumping of Clean Fresh Water at a temperature of +5°C to +40°C to: Garden Taps, Garden Sheds or similar, Clean Water Transfer, and 
for  no  other  use.    It  is  not  intended  for  use  for  whole-of-house  supply  or  commercial  applications.  It  must  not  be  used  in  hazardous 
locations, or for liquids other than clean water, or in continuous running applications, or in applications that require frequent starting and 
stopping.  
 
IMPORTANT: Ensure the pump is the right size for your application, before you install it.  A pump that is under-sized is not faulty, and is not 
covered by warranty. Ensure the right size piping is used, small pipes will reduce performance and will cause the pump to use much more 
power, costing you a lot of money in the long term! See 8 in the instructions below for further information 

 

MODEL 

POWER 

OUTLET 

RATED 

MAXIMUM 

WATER 

OUTLET 

SIZE 

 

AMPS 

WATTS 

MM 

INCH 

FLOW 

(lpm) 

HEAD 

(m) 

FLOW 

(lpm) 

HEAD 

(m) 

NUMBER 
OF TAPS

LxWxH (mm) 

DT42 

2.5 

370 

25 

23 

18 

37 

37 

2-3 

260x180x340 

NOTES:  Performance data quoted is generally from test data, and can vary, and does not take into account factors in the installation such as loss of pressure and flow due to pipework  
& pipe-fittings & valves.  Product depicted may differ from the product supplied, due to design changes or improvements. *Amps and Wattage vary according to the load on the motor.   

 
INSTALLATION GUIDELINES 

Please read and follow the instructions.  Warranty is voided if the instructions are not followed.  
 

1.

  

IMPORTANT MANDATORY REQUIREMENTS FOR ALL INSTALLATIONS:

  Before installing or servicing disconnect from the power supply. All 

pumps must be installed using barrel-union connections to facilitate easy servicing or replacement.  Ball-valves or gate-valves must be fitted on 
the suction, and the discharge, and the Town-water backup supply where fitted. A Y-Strainer or Pre-filter must be installed on the suction to 
prevent  particles  entering  the  pump.  Remove  all  swarf  from  the  tank  after  cutting  openings  etc  –  swarf  in  the  pump  voids  warranty.  All 
instructions are conditions of warranty; all warranty is void if instructions are not followed.   
It is recommended to install a Check-Valve in the discharge pipework, however DO NOT install the check valve directly on the discharge of the 
Pressure Controller, as this may cause it to malfunction, install the Check-Valve further down the pipe, before the first point of discharge.   
 

2.POSITION

 Do not position the pump where it could take in solids or sludge. This pump is not to be used as your sole water supply. For critical 

applications where loss of water supply could cause serious consequences, use a  DUAL PUMP System so you have a backup water supply or 
use a TOWN-WATER BACK-UP SYSTEM. This pump is not designed nor intended to be used for Fire Fighting purposes. 
 

3.PROTECT FROM THE WEATHER:

  The pump must be protected from the weather, by way of a plastic pump cover or  skillion roof cover, or 

similar. However the installer must ensure that there is adequate ventilation so the pump does not overheat. 

 