Waterpik Technologies Cascadia CF-200 Instruction Manual Download Page 1

Operation

To change settings, from 
either the full-body spray 
or the concentrated power 
spray, push the spray 
change button at the base 
of the showerhead so it 
extends to the opposite side 
of its current position.

Flow Control

Waterpik

®

 brand showerheads are equipped with an OptiFLOW

®

 regu-

lator that limits maximum water flow to 2.5 gallons per minute at 80 
psi as mandated by U.S. federal law. 
In areas with extremely low water pressure, causing  
the shower water flow to be unsatisfactory, the  
flow regulator may be removed to improve  
the water flow in the showerhead.  
To remove, unscrew  
filter screen by turning  
counterclockwise.  
Remove regulator  
with needle-nose  
pliers and replace  
filter screen.

1.   Remove old showerhead. Clean pipe threads 

thoroughly.

2.   Tighten the flexible shower arm onto the 

“J” pipe by hand, applying force to 
the nut closest to the “J” pipe. 
Do not use the flexible shower 
arm as a handle to tighten this 
connection.

3.   Attach the showerhead to the 

flexible shower arm by hand 
tightening the shower arm collar to the 
threaded end of the shower head.

4.   Be sure to properly align threads before tightening.
5.   Slowly turn on cold water and check for leaks. If leaks occur, 

retighten all connections.

6.   Do not use excessive force in positioning the showerhead and/or 

arm.

7.   If the showerhead is not maintaining its position, re-tighten the  

showerhead collar and shower arm nut.

Hand-Held Installation

1.   Remove old showerhead. Clean pipe threads thoroughly.
2.   Slightly loosen swivel collar on bracket.
3.   Hand tighten pivot ball to pipe.
4.   Hand tighten adaptor to showerhead.
5.   Hand tighten hose to adapter and bracket.
6.   Place showerhead in bracket.

Instruction Manual

drenching rain showerhead

Flexible Installation

Your new showerhead will fit a standard 1/2” shower “J” pipe. Do not  
attach this product to a plastic shower arm since it may not provide  
adequate support.
Tools are not required. Do not use pipe tape or any other sealants 
when installing the showerhead. These materials are not necessary 
and may cause the nut to loosen prematurely. Hand tightening is 
sufficient to secure the shower thread. Make sure the washer is in the 
end of the nut.

DATE: 18 May 2010    CLIENT: Water Pik, Inc.

FILENAME: FN20010910-FAD_Cascadia.indd

DESCRIPTION: Waterpik Cascadia Showerhead Instruction Manual

FILE TYPE: Adobe InDesign CS4

PREPARED BY: Brian Colon

FORM: 20010910-F AD

SIZE FLAT: 8.375” x 8.5” 

SIZE FOLDED: 2.8125” x 4.25”

FOLDS: Indicated

DIELINE: N/A

INK: Black

NOTES:

Troubleshooting Guide

Problem

Solution

No water flow from 

installed shower 

head:

a   Confirm previous shower washer is not in the 

j-pipe.

b   Confirm the hose is properly installed, try 

switching ends.

c   Confirm there is only one washer in the pivot ball.

Low water pressure 

or missing spray 

patterns

a   Clean shower head in vinegar/water solution. 

(See care section).

b   Clean screen and flow regulator.

Leaking at pipe pivot 

ball connection:

a   Confirm one single washer is seated on top of 

the screen.

b   Grate bar of soap across the j-pipe threads to act 

as a sealant.

Showerhead and/

or bracket stiff to 

change angle

a   Immerse pivot ball and large nut of the bracket in 

hot water or use a blow dryer for several minutes 

and then use a towel to loosen the large nut.

    

For Fixed Mount:

 install FM shower head to 

provide additional leverage to change angle of 

spray. (Contact Waterpik for further assistance).

Care and Cleaning

Clean the filter screen at least once a year, or when you notice a drop in 

water pressure. To remove, unscrew the nut from the pipe. Remove the 

screen by turning it counter-clockwise (pliers may be used) and rinse.
If you remove the flow regulator, be sure you reinstall it with the black 

O-ring facing out.
•   Cleaning is required when mineral deposits appear on the spray 

holes to maintain proper working conditions.

•   Clean the flexible nozzles by rubbing with a finger or soft bristled 

toothbrush. Clean by soaking in household vinegar.

•   Do not clean or rinse any part with harsh chemicals, heavy-duty 

cleaners or abrasives. This may damage parts or finish and may void 

the warranty.

Limited Lifetime Warranty

Water Pik, Inc. warrants to the original purchaser of this product that it is 

free from defects in material and workmanship for as long as the original 

purchaser owns this product. Water Pik, Inc. will replace any part of the 

product which in our opinion is defective, provided that the product has 

not been abused, misused, altered or damaged after purchase. (This 

includes damage due to use of tools or harsh chemicals.) In the event 

an item has been discontinued we will replace with what we deem to be 

the closest product. Water Pik, Inc. is not responsible for labor charges, 

installation, or other consequential cost. The responsibility of Water Pik, 

Inc. shall not exceed the original purchase price of the product. This 

warranty gives you specific legal rights. You may also have other rights 

that vary where you reside. Save your receipt as proof of purchase is 

required for warranty action. 

Have any questions or need assistance?

If in the U.S., call our toll-free 

Customer Assistance Line,
1-800-525-2774
www.waterpik.com

If outside the U.S., write us at:  
Water Pik, Inc. 
1730 East Prospect Road 
Fort Collins, CO 80553-0001 USA

Waterpik

®

 (stylized) is a trademark of Water Pik, Inc. registered in the EU, 

Switzerland, Mexico, Canada, and United States.
Waterpik

®

 is a trademark of Water Pik, Inc. registered in Argentina, Australia, 

Austria, Canada, China, Czech Republic, Hungary, India, Japan, Poland, Russian 
Federation, South Africa, Switzerland, Ukraine, and the United States.
Cascadia

®

 is a trademark of Water Pik, Inc. registered in Australia, Canada, EU, 

Switzerland and the United States.
Optiflow

®

 is a trademark of Water Pik, Inc. registered in Australia, Canada, the EU, 

Korea and the United States.
© 2010 Water Pik, Inc.

Water Pik, Inc. 
1730 East Prospect Road, Fort Collins, CO 80553-0001 USA 
www.waterpik.com 

FN 20010910-F AD

Nut

Flow Regulator  

(black O-ring 

faces out)

Washer

Filter Screen

Filter  

Screen

Flow Regulator

Spray Change Button

Spray Change Button

Shower  

Arm Nut

Adapter

Spray Change 

Button

5’ hose

Models:

CF-200
CF-201

CF-201C
CF-203C
CF-209C

CF-261

CF-263C

Collar

Flexible Arm

Spray Change 

Button

Bracket