WATEROUS COMPANY
•
125 HARDMAN AVENUE SOUTH
SOUTH ST. PAUL, MINNESOTA 55075-2456 U.S.A.
Phone: (651) 450-5000
FAX: (651) 450-5090
Page 1: ...ooting 10 Pump Repair Parts 11 Float and Fuel System 12 Exhaust and Air Intake Prior to 7 21 06 13 After 7 21 06 14 Pump 15 Engine Starter and Ignition 16 Engine Carburetor and Power Head 17 Warranty...
Page 2: ...owing instructions include operation maintenance and a list of repair parts for your Floto Pump Before operating your Floto Pump you need to get the proper fire fighting training and protective clothi...
Page 3: ...ith spark plug removed use an approved tester 9 DO NOT crank engine with spark plug removed If the engine floods place throttle in FAST and crank until engine starts 10 DO NOT use the pump to pump fla...
Page 4: ...reases the danger of personal injury Do not tamper with the governor springs governor links or other parts which may cause an increase in governed engine speed Do not tamper with the engine speed sele...
Page 5: ...WARNING DECALS Page 4 of 18 Warning Carbon Monoxide Warning Hot Surface Warning Hearing Protection Required IL2391...
Page 6: ...OPERATION Page 5 of 18 Throttle Float Air Intake Recoil Starter Fuel Tank Muffler On Off Switch Discharge Throttle Arm IL2394 Cap Vent Choke Lever Shown in Open Position Pump Operating Features...
Page 7: ...ed to prevent wind or current from swinging it back 3 Open vent in fuel tank cap by turning it counterclock wise 4 Move ignition switch to RUN on and close choke by moving choke lever in direction of...
Page 8: ...r and engine sur faces will become hot during operation Use a tool and or gloves to prevent burns while using the compression release 1 Prior to starting the engine engage the compression release by d...
Page 9: ...ation under a load will determine the best setting 3 Adjust the low speed idle needle first and accelerate If the engine bogs down or accelerates slowly turn the low speed idle needle clockwise until...
Page 10: ...ump to float Disconnect and plug fuel line at carburetor and lift engine and pump assembly out of float Remove four self locking nuts and plain wash ers and lift off lower volute Thoroughly clean impe...
Page 11: ...ine misses Dirt in fuel line or carburetor Remove and clean 4 Engine misses Carburetor improperly adjusted See Operating Instructions under Carburetor Ad justment Spark plug fouled broken or incorrect...
Page 12: ...R PARTS Page 11 of 18 Refer to the following pages Float and Fuel system 12 Exhaust and Air Intake Prior to 7 21 06 13 After 7 21 06 14 Pump 15 Engine Starter and Ignition 16 Engine Carburetor and Pow...
Page 13: ...P decal 50 Fuel mix decal 51 Name plate decal includes pump serial number REF DESCRIPTION NO 77 Hearing protection warning decal 79 Patent decal 80 Folding spanner wrench 90 Fuel tank subassembly incl...
Page 14: ...32 x 3 8 in 29 Socket hd screw 1 4 20 x 2 1 2 in 35 Self locking nut no 10 24 REF DESCRIPTION NO 42 Lock washer internal tooth 1 4 in 44 Muffler 45 Exhaust adapter 48 Choke decal prior to 05 19 03 Cho...
Page 15: ...w no 10 32 x 3 8 in use Loctite 242 Blue on screws 29 Socket hd screw 1 4 20 x 2 1 2 in 35 Self locking nut no 10 24 REF DESCRIPTION NO 42 Lock washer internal tooth 1 4 in 44 Muffler 45 Exhaust adapt...
Page 16: ...le 1 1 2 NH not used with REF NO 36 NPSH or BSD discharge nozzles 46 O ring 7 14 x 7 1 2 in 131 Woodruff key HIGH PRESSURE FLOTO REF DESCRIPTION NO 7 Engine 12 Hex hd screw 3 8 16 x 1 1 2 in 13 Self l...
Page 17: ...cap screw with lockwasher 1 4 20 x 5 8 in 128 Hex hd cap screw with lockwasher 1 4 20 x 1 2 in REF DESCRIPTION NO 135 Hex hd screw 1 4 20 x 5 8 in 136 Hex nut 7 16 20 138 Starter cup 139 Flywheel 141...
Page 18: ...Head gasket 032 in thick 114 Head gasket 062 in thick 115 Cylinder w seal REF DESCRIPTION NO 116 Reed 117 Drive end seal 118 Crankcase cover gasket 119 Transfer port cover 120 Connecting rod screw 12...
Page 19: ...roducts shall be the warranty provided by the manufacturer thereof which if assignable WATEROUS will assign to Buyer if requested by Buyer c any product or part altered modified serviced or repaired o...
Page 20: ...WATEROUS COMPANY 125 HARDMAN AVENUE SOUTH SOUTH ST PAUL MINNESOTA 55075 2456 U S A Phone 651 450 5000 FAX 651 450 5090...