Use the illustration and instructions to install the 1
inch DLA. To connect to the apparatus plumbing,
refer to:
1 Connect the split CANbus cable to the CANbus
connector on the node controller.
2 Connect the male end on the split CANbus
cable to an upstream node controller, or to the
PDM control box—the discharge CANbus
connection.
Note:
Use a CANbus extension cable if
necessary.
3 Connect the female end on the CANbus splitter
cable to the next, downstream node controller,
or to a terminating resister if this is the last
downstream node controller in the system.
Note:
Use a CANbus extension cable if
necessary.
4 Locally source a Deutsch DT06-2S connector
and an appropriate cable to connect apparatus
power to the node controller. Power the node
controller through a 10 A circuit breaker.
5 Connect the DLA inlet to the concentrate
supply.
6 Connect the DLA outlet to the discharge.
7 Install the paddlewheel flowmeter into the
associated discharge, upstream of the DLA
outlet connection.
8 Use an M12 cable extension to connect the
node controller to the paddlewheel flowmeter.
Note:
Use additional M12 cable extensions if
necessary.