Maintenance

Wall Mount Bracket

Filter Housing Head

O-Rings

Filter Housing Bowl

Housing Spanner

3   Clean bowl(s) with soap and warm water and rinse thoroughly. Check O-Ring(s) for 

damage and if there is any, replace.

4   Check O-ring(s) lubrication and if necessary apply a light coating of food grade 

silicone lubricant (or similar).

5   Remove all packaging from new filter cartridge(s) and insert into housing bowl(s) 

making sure cartridge(s) is properly seated over spigot in base of bowl(s). 
Remember to record the model no. of the cartridge(s) you use.

6   Hold bowl(s) upright while screwing onto head. Make certain that the spigot in the 

housing head(s) is located centrally to the cartridge(s) to make a good seal. Hand 

tighten bowl until firm. DO NOT OVER TIGHTEN.

7   Open downstream tap to allow air to be released and gently open water supply 

allowing all air to be purged.

8   Allow water to run for 2 minutes to flush the system.

9   Close down stream tap and check for leaks. Flush system for 10 minutes after any 

period of non-use more than 2 days. For a period of non-use of 2 weeks or more, 
it may be necessary to replace the cartridge.

Replacement Parts List

 345 

 345 

 150 

 209 

 150 

 209 

 345 

 209 

 345 

Summary of Contents for Puretec WH1

Page 1: ...instructions NOV2021 Whole House Water Filtration Systems WH1 WH2 EM1 EM2 DO DO LIQ SU RE NO SURGE PROTECTION REQUIRED NO EXTENSION CORDS 181 209 150 181 337 209 150 379 337 209 345 181 589 209 181 3...

Page 2: ...ns For other types of water supply please contact your local Puretec stockist or call our Puretec Customer Service Helpline The Puretec filter systems cartridges need replacing regularly to maintain o...

Page 3: ...fection This product must be installed in accordance with local plumbing regulations by a licensed plumber Installation Note A water filter system tap like any product has a limited life and may event...

Page 4: ...se it to split Warning Use PTFE thread seal tape on all connections Use of pipe sealants will void warranty 4 If using sweated fittings allow enough time to cool before connecting to the housing 5 Sec...

Page 5: ...n performance and warranty use genuine Puretec replacements Cartridge Installation Replacement To change the filter cartridge s please adhere to the following procedure 1 Turn water supply off and rel...

Page 6: ...igot in base of bowl s Remember to record the model no of the cartridge s you use 6 Hold bowl s upright while screwing onto head Make certain that the spigot in the housing head s is located centrally...

Page 7: ...liable for damages consequential or otherwise or delays caused or faulty manufacturing except as excluded by law Applicable to all above is that the Warranties need to be approved by Puretec to ensure...

Page 8: ......

Reviews: