background image

 

WL800

 Manual 

                                                                         Page 64 – Revision 12‐11‐2018 

 

 
Heating and Service LED Alternate Blinking –Low Water Level Error 

 

Possible Reason 

Solution 

Full level sensor has detected 
water, but low level is not 
detected 

Check connection to low water level sensor. 
 
Replace low water level sensor. 

 

 

Chilling and Service LED Alternate Blinking – Full Water Level Error 

 

Possible Reason 

Solution 

Low Level and Overflow 
Sensors indicted water but full 
level sensor is not detected 

Check connection to low water level sensor. 
 
Replace full water level sensor. 

 

 

Heating, Chilling and Service LED Sequentially Blink 

 

Possible Reason 

Solution 

Overflow sensor has detected 
water but neither low or full 
sensors are detected 

Check connections to both low and full water sensors. 
 
Replace both Low Water and Full Water Sensors. 

 
 
Heating, Chilling and Service LED Blinks Simultaneously  

 

Possible Reason 

Solution 

All three level sensors have 
detected water 

Check Feed Valve for Debris. 
 
Clean or replace feed valve. 

 
 
Service LED is On – Leak Detection Probe Has Detected Water 

 

Possible Reason 

Solution 

Dry inside of unit and leak 
detector. 

Check unit for leak and repair or replace faulty parts. 

 
 
 

 