WL380 FAULT CODE TROUBLESHOOTING 

 

1.

 

No Green LED Status Lights  
 

2.

 

Power Light Flashing Green and Continuous Audible Alarms – Leak Detected 
 

3.

 

Firewall Purification Light Out and 20 Second Audible Alarm 

 

1.

 

 FAULT CODE:

  No Green LED Status Lights 

 

 

 

Possible Reason 

Solution 

Power Problem 

 
Are red and green switches on back Illuminated?   
  Yes – Check Power supply to front PCB 
  No ‐ Check for power disruption.   
 
Does outlet have power? 
  Yes‐ Check Power Cord to ensure it is properly seating in     
both sockets and in good condition.  Then check 15‐amp 
Fuse 
  No – Check GFCI or Circuit Breaker to reestablish power 
 

Front PCB Issue 
No Power 

 
Check white 24 VDC power supply line is connected to the 
front PCB is supplying 24VDC.  – replace Transformer if no 
24VDC supply  
See Power Troubleshooting for more details. 
 

 