WL2FLT Manual                                                                                                                                 Page 42 – Revision 7-19-21 

 

2.

 

Red Heater & Compressor Power Switch is lit but the Red LED on the Front is not 

lit  

 

 

Possible Reason 

Solution 

Bad Transformer 

Replace Transformer 

Black Power Connector to the 

PCB is not properly connected  Properly connect. 

Bad Front PCB  

Replace Front PCB 

Defective Red Heater & 

Compressor Switch 

Replace Red Heater & Compressor Switch 

 

 

3.

 

Compressor Runs But Does Not Chill 

 

 

Possible Reason 

Solution 

Condenser is dirty 

Clean the condensing coil of any obstructions or dust. 

Reduction of airflow into unit.  Make sure unit is not under minimum ventilation requirements (2 

to 4 inches). 

Compressor is running very 

hot. 

Low or lost refrigerant.   

 

Counter Top should be 40 grams (1.41 ounces) 

Tower should be 65 grams (2.29 ounces) 

 

Refrigerant recharge as necessary. 

 

 

 