WL250
Operating,
Installation,
and
Service
Manual
Page
20
‐
Revision:
4
‐
25
‐
2016
1.
Attach
the
water
supply
line
to
the
1/4”
feed
water
inlet
bulkhead
fitting
on
the
back
of
the
WL250
Water
Treatment
System.
Waterlogic
requires
the
use
of
a
water
pressure
regulator.
Water
feed
pressure
must
be
between
40
‐
60
psi.
Turn
on
the
water
supply
and
check
for
leaks.
2.
Check
to
ensure
that
the
Red
Heater
and
Compressor
Power
Switch
is
the
O=OFF
p
osition.
NOTE:
Switches
have
internal
LED
that
illuminates
when
placed
in
I=ON
position.
3.
Connect
the
power
cord
to
the
back
of
the
Waterlogic
WL250
Water
Treatment
System
and
to
a
120
Volt
supply.
4.
Fill
the
Cold
Tank.
Hold
a
container
under
the
dispensing
faucet,
press
and
hold
the
main
dispensing
button
until
a
continuous
flow
of
water
is
obtained.
Once
a
continuous
flow
is
obtained,
release
the
dispensing
button.
Cold
tank
is
now
full.
5.
Fill
the
Hot
Tank.
Hold
a
container
under
the
dispensing
faucet.
Press
the
Hot
Select
Button
followed
by
the
main
dispensing
button
until
a
continuous
flow
of
water
is
obtained.
Once
a
continuous
flow
is
obtained,
release
the
main
dispensing
button.
Hot
tank
is
now
full.
CAUTION!
NEVER
TURN
ON
HEATER
BEFORE
FILLING
HOT
TANK.
Red
Heater
and
Compressor
Power
Switch
must
be
in
the
O=OFF
position
while
the
hot
tank
is
empty.
Damage
could
occur
within
one
minute
and
the
overload
(high
limit)
will
require
manual
reset
if
heater
is
turned
on
with
an
empty
hot
tank.
6.
Verify
that
the
UV
lamp
operates
as
expected.
WARNING!
ULTRAVIOLET
RADIATION.
Protect
your
skin
and
eyes
against
ultraviolet
rays.
Never
look
directly
at
an
operating
UV
light.
Always
disconnect
before
removal.
7.
Move
the
Waterlogic
WL250
Water
Treatment
System
into
its
final
operating
position.
Be
sure
that
a
minimum
of
2”
clearance
is
maintained
around
both
sides
and
the
back
of
the
WL250
Water
Treatment
System.
This
is
important
to
allow
proper
airflow
and
heat
exchange
of
refrigeration
system.
8.
Level
WL250
Water
Treatment
System
using
the
adjustable
feet
to
level
if
necessary.
Never
install
on
incline.
9.
Turn
the
Red
Heater
and
Compressor
Power
Switch
to
I=ON
position.
10.
When
the
WL250
Water
Treatment
System
has
reached
its
Hot
Temp
Set
Point,
the
heater
will
cycle
off.
When
the
WL250
Water
Treatment
System
has
reached
its
Cold
Temp
Set
Point
Temperature,
the
compressor
will
cycle
off.
11.
Once
the
WL250
Water
Treatment
System
is
at
the
target
temperature(s),
sample
the
water
to
ensure
water
meets
expectations
and
additional
rinsing
or
adjustment
is
not
required.
12.
Check
the
WL250
Water
Treatment
System
for
any
leaks.
External
Leak
Protection
is
always
recommended.