Red Heater and Compressor
Switch on unit is off.
Turn Red Heater and Compressor Switch on.
I = ON
Loose connection(s) on the
Display PCB
Turn power off; unplug the unit and visually inspect solenoid
connections into the Display PCB. Verify the soldering points
on connections are secure into the board.
Remove the PCB to inspect the front of the board.
Exhausted Filter
Replace filters as needed.
8.
Cold Water Dispenses from Faucet and Vent Outlet Simultaneously
Possible Reason
Solution
Improper tubing attachment
from the tank to faucet or vice
versa
Verify tubing is connected properly from tank outlets to
correct faucet attachments.
Scale has formed inside cold
tank outlet tube.
Remove cold water outlet tube from tank to faucet. Pour
some scale remover into cold tank.
Expansion chamber in Cold
Tank is not sealed properly.
Replace Cold Tank.