background image

 

WL200

 

Operating,

 

Installation,

 

and

 

Service

 

Manual

                                                                      

Page

 

6

 ‐ 

Revision:

   

4

13

2016

 

SAFETY

 

PRECAUTIONS

 

 

Basic

 

safety

 

precautions

 

should

 

be

 

followed,

 

including

 

the

 

following:

 

 

      

DANGER!

  

If

 

incorrectly

 

installed,

 

operated

 

or

 

maintained,

 

this

 

product

 

can

 

cause

 

death

 

or

 

severe

 

injury.

 

Those

 

who

 

install,

 

operate,

 

or

 

maintain

 

this

 

product

 

should

 

be

 

trained

 

in

 

its

 

proper

 

use,

 

warned

 

of

 

its

 

dangers,

 

and

 

should

 

read

 

the

 

entire

 

manual

 

before

 

attempting

 

to

 

install,

 

operate,

 

or

 

maintain

 

this

 

product.

 

 

     

WARNING!

  

Unit

 

is

 

to

 

be

 

used

 

for

 

its

 

intended

 

purpose

 

as

 

described

 

in

 

this

 

manual,

 

and

 

untrained

 

individuals

 

who

 

use

 

this

 

manual

 

assume

 

the

 

risk

 

of

 

any

 

resulting

 

property

 

damage

 

or

 

personal

 

injury.

 

 

     

DANGER!

 

ELECTRICAL

 

SHOCK

 

HAZARD

.

  

Always

 

unplug

 

from

 

power

 

supply

 

prior

 

to

 

servicing

 

equipment

 

to

 

prevent

 

electrical

 

shock.

 

 

     

WARNING!

 

This

 

system

 

to

 

be

 

used

 

for

 

water

 

only

 

and

 

is

 

not

 

intended

 

for

 

use

 

where

 

water

 

is

 

microbiologically

 

unsafe

 

or

 

with

 

water

 

of

 

unknown

 

quality

 

without

 

adequate

 

disinfection

 

before

 

or

 

after

 

the

 

system.

  

The

 

system

 

is

 

designed

 

for

 

the

 

supplemental

 

bactericidal

 

treatment

 

of

 

either

 

treated

 

and

 

disinfected

 

public

 

drinking

 

water,

 

or

 

other

 

drinking

 

water,

 

which

 

has

 

been

 

tested

 

and

 

deemed

 

acceptable

 

for

 

human

 

consumption

 

by

 

the

 

state

 

or

 

local

 

health

 

agency

 

having

 

jurisdiction.

  

The

 

system

 

is

 

designed

 

to

 

reduce

 

normally

 

occurring

 

non

pathogenic

 

or

 

nuisance

 

microorganisms

 

only.

  

System

 

is

 

not

 

intended

 

for

 

treatment

 

of

 

contaminated

 

water.

 

 

     

WARNING!

  

Dispenser

 

Could

 

Tip

 

or

 

Fall

 

causing

 

serious

 

injury.

  

Always

 

install

 

unit

 

on

 

a

 

firm,

 

flat,

 

and

 

level

 

surface

 

and

 

secure

 

the

 

WL200

 

to

 

the

 

base

 

cabinet

 

with

 

the

 

screw

 

provided

 

to

 

lock

 

the

 

components

 

together.

  

Never

 

place

 

heavy

 

items

 

on

 

top

 

of

 

unit

 

and

 

never

 

climb,

 

stand,

 

or

 

hang

 

on

 

unit

 

or

 

storage

 

cabinet

 

to

 

prevent

 

injury

 

and

 

damage.

 

       

 

 

CAUTION!

 

INDOOR

 

USE

 

ONLY.

  

Do

 

not

 

install

 

outdoors

 

or

 

where

 

unit

 

is

 

in

 

direct

 

sunlight.

  

Do

 

not

 

install

 

where

 

ambient

 

temperature

 

goes

 

below

 

50F

 

or

 

above

 

97F.

  

Avoid

 

high

 

humidity

 

and

 

moisture.

  

Product

 

life

 

and

 

performance

 

will

 

be

 

impacted

 

and

 

warranty

 

could

 

be

 

voided.

 

 

 

Summary of Contents for WL200

Page 1: ...aterlogic Commercial Products LLC 11710 Stonegate Circle Omaha NE 68164 800 288 1891 www waterlogic us Tech Portal Website http techportal waterlogic com WL200 OPERATING INSTALLATION AND SERVICE MANUA...

Page 2: ...The Waterlogic WL200 provides exceptional quality and great tasting water with every use TABLE OF CONTENTS Features and Benefits 3 Certifications 4 Introduction and Safety Alert Symbols 5 Safety Preca...

Page 3: ...ty Counter Top has 2 liters of Cold Water Capacity BioCote Anti Microbial Protection Plastic surfaces surrounding dispensing areas and drip tray are infused with an exclusive silver additive called Bi...

Page 4: ...or Drinking Water Coolers BPA Free Waterlogic tests for BPA and declares that all of its products are Bisphenol A FREE and contain no harmful BPA plastics Waterlogic manufacturing is certified to ISO...

Page 5: ...ufactured and marketed by Waterlogic and its affiliates are protected by patents issued or pending in the United States and other countries Waterlogic reserves the right to change the specifications r...

Page 6: ...water of unknown quality without adequate disinfection before or after the system The system is designed for the supplemental bactericidal treatment of either treated and disinfected public drinking w...

Page 7: ...Maximum Service Pressure 100 psi 689 kPa Use Pressure Regulator Rated Service Flow 0 5 gallons per minute 1 89 Lpm Environmental Temperature 35 100 F 2 37 C Refrigerant Gas R134a 40g 1 41 ounces R134a...

Page 8: ...llation and Service Manual Page 8 Revision 4 13 2016 OPERATING INSTRUCTIONS The above picture shows front LCD display and control panel for the Waterlogic WL200 For Cold Water Press the Dispensing But...

Page 9: ...WL200 Operating Installation and Service Manual Page 9 Revision 4 13 2016 WL200 COUNTER TOP WATER FLOW DIAGRAM...

Page 10: ...WL200 Operating Installation and Service Manual Page 10 Revision 4 13 2016 Water In Filter Dryer Solenoid Valve Compressor Condenser Water Out Faucet WL200 TOWER WATER FLOW DIAGRAM...

Page 11: ...erature and the range is approximately 20 F thru the full range of adjustment 7 00 to the 5 00 positions You should be able to turn the screw from the factory set point of 41 F 12 00 position about 45...

Page 12: ...nd check exterior for damage Sanitizing Sanitize using a Household Bleach 5 25 Sodium Hypochlorite solution or other approved cleaner throughout the cold and sparkling water circuits Follow all instru...

Page 13: ...nd specified to do the job given the local water conditions usage maintenance schedule and placement restrictions In order for the filters to perform as represented and to provide the best quality wat...

Page 14: ...faucet of the WL200 11 Flush the Cold Tank Run several gallons of water through the faucet by dispensing cold water to dilute and remove the sanitizer from the cold circuit You can use chlorine test s...

Page 15: ...Red Power Switch to disable compressor O OFF Turn off Water Supply and Bleed Water Pressure 2 Isolate the unit from feed water by turning off the supply 3 Dispense cold still water to relieve any pre...

Page 16: ...Installation and Service Manual Page 16 Revision 4 13 2016 8 Disconnect tubing from inlet elbow from solenoid and allow water to drain 9 Reconnect tubing into inlet elbow 10 Dry inside of unit 11 Repl...

Page 17: ...ater Supply and Bleed Water Pressure 2 Isolate the unit from feed water by turning off the supply 3 Dispense cold still water to relieve any pressure built up in the system 4 Remove the water supply l...

Page 18: ...w 35 F 2 C Install indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser t...

Page 19: ...of water is obtained Once a continuous flow is obtained release the dispensing button Cold tank is now full 5 Move the Waterlogic WL200 into its final operating position Be sure that a minimum of 2 cl...

Page 20: ...or damage DANGER HIGH VOLTAGE ELECTRICAL HAZARD Unplug before inspection and service 2 Ensure there is adequate minimum of 2 clearance around the unit and clean the condenser grill and compressor fan...

Page 21: ...WL200 Operating Installation and Service Manual Page 21 Revision 4 13 2016 WL200 COUNTER TOP DRAWINGS with PART NUMBERS Wetted Parts...

Page 22: ...CT 2016 Cold Tank Thermostat included with Cold Tank 12 1101 Yes 4 ST 8216 Silver Back Panel Counter Top Only 12 8061 Yes 5 EL 5016 Power Line Noise Filter ElectroMagnetic Interference filter EMI 10...

Page 23: ...Feet Counter Top Only 12 3150 Yes 13 PU 4008 A 1 4 Union Elbow John Guest P N P10308S Purchase from John Guest No 14 PU 4016 Solenoid Valve 1000 mm 12 1500 Yes 14 1 CU 0001 Solenoid Cushion CU 0001 Ye...

Page 24: ...8605 Yes 21 PL 1100 Silicon Button Key Mat Cold only 12 8600 Yes 22 PL 0084 L00 CL Front Upper Insert Panel Charcoal NA No 23 LP 7085 Button Label Cold only 12 8610 Yes 24 PL 1152 Drip Tray Grill Char...

Page 25: ...Counter Top Only 12 3165 Yes 32 CT 2060 2L UV Cold Tank Assembly Counter Top Only 12 3110 Yes 33 EN 6111 A Leak Detection PCB NA No 33 1 EN 6059 PCB Stand off Pin 10 3017 Yes 34 PU 4007 A 5 16 x Reduc...

Page 26: ...WL200 Operating Installation and Service Manual Page 26 Revision 4 13 2016 WL200 TOWER DRAWINGS with PART NUMBERS Wetted Parts...

Page 27: ...15A with One Wire EL 5053 Yes 3 1 EL 5010 Fuse 120V 15A 10 3013 Yes 4 EL 5019 A Red Power and Compressor Switch 12 5600 Yes 5 CT 2016 Cold Tank Thermostat included with Cold Tank 12 1101 Yes 6 ST 813...

Page 28: ...12 1500 Yes 13 1 CU 0001 Solenoid Cushion CU 0001 Yes 14 PU 4008 A 1 4 Union Elbow John Guest P N P10308S Purchase from John Guest No 15 PU 4007 A 5 16 x Reducing Elbow John Guest P N PI211008S Purcha...

Page 29: ...146 Front Upper Drip Tray Insert Panel 12 8050 Yes 21 EN 6086 PCB for Cold Water 12 8615 Yes 22 PL 1180 CN PCB Cover 12 8605 Yes 23 PL 1100 Silicon Button Key Mat Cold only 12 8600 Yes 24 PL 0084 L00...

Page 30: ...2017 4L Single Cold Tank Assembly Tower Only 12 1100 Yes 30 EL 5003 A Power Transformer 120V 12 3117 Yes 31 ST 8136 R2 Upper Shelf Tower Only 12 8003 Yes 32 CO 9027 Wire Condenser Tower Only 12 8102 S...

Page 31: ...Service Manual Page 31 Revision 4 13 2016 WL200 COUNTER TOP ELECTRICAL DIAGRAM DANGER HIGH VOLTAGE ELECTRICAL HAZARD PCB Printed Circuit Board contains High Voltage Only trained and qualified technic...

Page 32: ...and Service Manual Page 32 Revision 4 13 2016 WL200 TOWER ELECTRICAL DIAGRAM DANGER HIGH VOLTAGE ELECTRICAL HAZARD PCB Printed Circuit Board contains High Voltage Only trained and qualified technician...

Page 33: ...run out of cold water Cold tank capacity is 4 liters for Tower and 2 liters for Counter Top Wait for cold tank to chill water to temperature prior to dispensing more cold water A greater capacity of W...

Page 34: ...mer Black Power Connector to the PCB is not properly connected Properly connect Bad Front PCB Replace Front PCB Part Number EN 6086 Waterlogic P N 12 8615 Defective Red Power Compressor Switch Replace...

Page 35: ...ition Turn Red Power and Compressor Switch on I ON Compressor Starting Circuit Turn Red Power and Compressor Switch off O OFF Remove the compressor cap on side of the compressor Disconnect the black a...

Page 36: ...ng won t stop when not holding the Dispensing Button 3 Steady Drip out of Faucet 4 Water does not dispense from unit 5 Cold Water dispenses from Faucet and Vent Outlet Simultaneously 6 Small amount of...

Page 37: ...PCGB or Solenoid Connector Check that they are connected properly and tightened Solenoid If both the Water Pressure and PCB have been ruled out then it is the Solenoid Replace Solenoid Dispensing butt...

Page 38: ...ch on unit is in the off position Turn Red Power and Compressor switch on I ON 15 Amp Fuse Blown Replace the 15 Amp Fuse as needed Water is present in the bottom tray causing the leak detection to tri...

Page 39: ...enses from Faucet Automatically Possible Reason Solution Cold or Hot Water solenoid valve malfunction Inspect valve components for proper function Replace as necessary Obstruction in solenoid housing...

Page 40: ...leased to the faucet The inlet solenoid controls flow into the tanks The tanks will depressurize once the dispense button is released the inlet solenoid closes A small amount of water will Run On thro...

Page 41: ...tion to Waterlogic for evaluation The form is available at www waterlogic us Supporting documentation must include but is not limited to proof of purchase installation date failure date and supporting...

Reviews: