SERVICE REQUIREMENTS
WARNING!
Read and understand the contents of this manual before attempting to service
WL1000GF MAX Water Treatment System. Failure to follow the instructions in this manual
could result in death, serious personal injury, or severe property damage. Only trained and
qualified technicians should attempt to install, maintain, or service Waterlogic Equipment.
1. Visually inspect all electrical and water connections for signs of wear or damage.
DANGER!
HIGH VOLTAGE ELECTRICAL HAZARD.
Unplug before inspection and service.
2.
Waterlogic
recommends changing the UV Lamp Assembly and Wiring Harness must be replaced
every 12 months.
WARNING!
ULTRAVIOLET RADIATION.
Protect your skin and eyes against ultraviolet rays.
Never look directly at an operating UV light. Disconnect before removing UV Lamp.
CAUTION!
UV LAMPS ARE HAZARDOUS.
Lamps are considered Hazardous Waste and must
be disposed of accordingly.
3. Clean the Quartz Sleeve that surrounds the UV lamp with a non-abrasive cloth, descaling
solution, or ultrasonic bath if needed when changing UV Lamps.
CAUTION!
UV SYSTEM IS FRAGILE.
Never handle the UV lamp or Quartz Sleeve with bare
hands. UV Lamp and quartz sleeve must be free of oils and contaminants to ensure proper
operation. Use a soft non-abrasive cloth to clean.
4. Inspect the Quartz Sleeve O-ring for wear or damage and replace as necessary.
5. Ensure there is adequate (minimum of 50mm) clearance around the unit and clean the condenser
grill and compressor fan to provide efficient cooling system operation.
6. Sanitise the Cold Tank as per instructions in the pre-installation procedures.
7. Clean and sanitise and descale external surfaces of the unit. Use only chemicals that are
compatible with ABS plastic and will not damage or degrade the product surfaces.
8. Remove descale, sanitise and clean the Faucet. Replace as needed.
WARNING!
SANITISER MAY CONTAIN HAZARDOUS CHEMICALS.
Use of proper personal
protective equipment such as rubber gloves and eye protection is required.
NOTE:
The Glow Starter shown may
appear blackened which is normal.
8w UV Lamp Assembly
Part Number CT-2083