WL Max Technical Manual - Version 1 - May 2013
INSTaLLaTION KIT
The WL Max must be installed according to the local guidelines and a pressure
reducer must be installed as part of the installation. The pressure reducer should
not be set higher than 3bar.
• The WL Max should not be connected to water supplies of unknown bacterial
quality or those not already fit for human consumption. The WL Max should only be
connected to a Potable drinking water supply.
• The filter on the WL Max must be changed every 6 months.
• The UV lamp on the WL Max must be changed every 6 months.
• The cold reservoir should also be flushed and sanitised every 6 months.
• Waterlogic International strongly recommends the use of an anti-flood device.
• Figure 1 is the recommended installation kit.
Fig 1. Waterlogic
Installation Kit
1 - 15mm Compression Inlet
2 - Double Check Valve (great for carbonated water)
3 - Adjustable Pressure Reducing Valve
4 - Integral Isolator
5 - Pressure Gauge Port
6 - Waterblock
7 - 1/4” Pushfit Outlet
The part number for the installation kit shown below is “P-KIT INSTALLATION”.
Your WL Max is generally ready for use.
Dispensing your choice of water is very simple, as follows:
1
. Place your cup centrally in the dispensing area for single faucet or on the edge for
the double faucet machine
2
. Select and hold the momentary dispense button until your cup has reached the
desired level, and then release the button.
3
. If using the auto-fill option, select the button until your container has reached the
desired level, then de-select the button
Operating Instructions
CONTINUOUS DISPENSE
Select the continuous dispense button, then remove your finger from
the button. When the container has reached the desired level de-
select the dispense button.
STOP DISPENSE
Put the dispense button into the central position to stop the dispensing
of water
PRESS aND HOLD DISPENSE
Select and hold the dispense button, release the button to stop the
dispensing of water