3. Wash hands thoroughly. Remove the replacement cartridge from its
box and its sani-sealed protective sleeve. Remove the protective cap.
Make sure the correct cartridge is installed in its socket according to
its colour. Locate the alignment tab on the top of the cartridge (there
are two at 180 degrees from each other) and align with the center front
of the cartridge socket. Push the cartridge straight up into the socket,
while turning ¼ turn to the RIGHT. The cartridge will engage and lock
into place.
Trouble
Causes
Solution
No water from the taps
Air entrance is blocked, or
connection is not turned on
Check connection to water line
No hot or cold water
1. Too much water used in a
short time
2. Electrical connection is
loose
1. Wait for unit to re-heat and
cool
2. Make sure the switch is ON
and the unit is plugged in
Loud noise or vibration
1. Incorrect placement
2. Foreign objects lodged in
the cooler
1. Refer to page 2 for correct
placement
2. Remove any foreign object
Water tastes different
1. Water storage tank is not
clean
2. Stored water has been
sitting too long
3. Filters need replacement
1. Clean storage tank
2.
Drain water and refill
3.
Replace filters
Inefficient water production
1. Main water valve is not
completely open
2.
Plugged filters
1. Open main water valve
2.
Replace filters
10. TROUBLESHOOTING
CAUTION: In order to avoid electrical damage, this unit must not be powered by an external device, interrupted by a timer, or
connected to a circuit that is regularly switched on and off.
CORRECT DISPOSAL OF THE UNIT: this product should not be disposed of with household waste. To prevent possible harm
to the environment, dispose of it according to local disposal and recycling programs.
9. WARRANTY
1. This unit is warrantied for failure by defects in material or workmanship for a period of 1 (one) year
from the date of purchase.
2. Any repairs under warranty must be performed by an authorized service center. When making a
claim under the warranty, the original proof of purchase must be supplied.
3. The warranty will be voided when one of the following occurs:
- Wear from normal use;
- Incorrect use, or unit has been abused or tampered with;
- Use of force or breakage from impact or heat.
4. Turn the cold water supply valve ON. Open the faucet and allow the system to run for two minutes
to flush. You may now resume normal use of the system.