3.  Wash hands thoroughly.  Remove the replacement cartridge from its 

box and its sani-sealed protective sleeve. Remove the protective cap.  

Make sure the correct cartridge is installed in its socket according to 

its colour. Locate the alignment tab on the top of the cartridge (there 

are two at 180 degrees from each other) and align with the center front 

of the cartridge socket.  Push the cartridge straight up into the socket, 

while turning ¼ turn to the RIGHT.  The cartridge will engage and lock 

into place. 

Trouble

Causes

Solution

No water from the taps

Air entrance is blocked, or 

connection is not turned on

Check connection to water line

No hot or cold water

1.  Too much water used in a 

short time

2.  Electrical connection is 

loose

1.  Wait for unit to re-heat and 

cool

2.  Make sure the switch is ON 

and the unit is plugged in

Loud noise or vibration

1.  Incorrect placement

2.  Foreign objects lodged in 

the cooler

1.  Refer to page 2 for correct 

placement

2.  Remove any foreign object 

Water tastes different

1.  Water storage tank is not 

clean

2.  Stored water has been 

sitting too long

3.  Filters need replacement

1.   Clean storage tank

2. 

 Drain water and refill

3. 

 Replace filters

Inefficient water production

1.  Main water valve is not 

completely open

2. 

Plugged filters

1.  Open main water valve

2. 

Replace filters

10. TROUBLESHOOTING

CAUTION: In order to avoid electrical damage, this unit must not be powered by an external device, interrupted by a timer, or 

connected to a circuit that is regularly switched on and off.

CORRECT DISPOSAL OF THE UNIT: this product should not be disposed of with household waste. To prevent possible harm 

to the environment, dispose of it according to local disposal and recycling programs.

9. WARRANTY

1.  This unit is warrantied for failure by defects in material or workmanship for a period of 1 (one) year 

from the date of purchase.

2.  Any repairs under warranty must be performed by an authorized service center. When making a 

claim under the warranty, the original proof of purchase must be supplied.

3.  The warranty will be voided when one of the following occurs:

     - Wear from normal use;

     - Incorrect use, or unit has been abused or tampered with;

     - Use of force or breakage from impact or heat.

4.  Turn the cold water supply valve ON.  Open the faucet and allow the system to run for two minutes 

to flush. You may now resume normal use of the system.

Summary of Contents for Apix CLSE-2200-HCSR

Page 1: ...POINT OF USE WATER COOLER WITH OPTIONAL FILTRATION SYSTEM VERY IMPORTANT PLEASE READ CAREFULLY BEFORE USE Winnipeg MB Canada ww waterite com MODEL CLSE 2200 HCSR OPERATION INSTRUCTIONS ...

Page 2: ...tap red 6 Drip tray 7 Lower front panel 8 Adjustable feet 9 Top cover 10 Thermostat 11 Fuse 12 Hot water switch 13 Drain cap 14 Inlet 15 Drain plug 16 Power cord 17 Ground wire 18 Condenser 2 INNER COMPONENTS 1 Air filter 2 Float valve 3 Cold water reservoir 4 Float sensor 5 Hot water tank 6 Compressor ...

Page 3: ...sible electric shock or fire 5 Clean outer surfaces with a soft cloth only Do not use chemical cleaners 6 Your cooler requires periodic sanitizing of internal components to inhibit bacterial growth We strongly recommend sanitizing with the WATERITE Biomax Cooler Cleaning Kit part N ACCS 0CK0 0001 every three months 7 Do not allow children to play with the RED hot tap 8 Do not move abruptly Do not ...

Page 4: ...y release carbon dust momentarily at initial start up but this is harmless and will clear immediately The first amount of filtered water needs to be discarded as it may contain debris form inside the storage tanks and filters Turn off the hot water switch and shut off the main water line Empty the unit by using the faucets and the drain valve Open the water line and let the unit refill completely ...

Page 5: ...g 3 Filters need replacement 1 Clean storage tank 2 Drain water and refill 3 Replace filters Inefficient water production 1 Main water valve is not completely open 2 Plugged filters 1 Open main water valve 2 Replace filters 10 TROUBLESHOOTING CAUTION In order to avoid electrical damage this unit must not be powered by an external device interrupted by a timer or connected to a circuit that is regu...

Page 6: ...on Sediment Filter V360112PP05 3 6 months Replacement Filter Kit 1 Carbon Block 1 Sediment V3602CRK 3 6 months RO Membrane V360312RO00 1 3 years UF Filter Cartridge V360312UF00 6 12 months UF Filter Replacement Kit 1 Carbon Block 1 Sediment 1 UF V360UFCRK 6 12 months 11 REPLACEMENT PARTS ...

Reviews: